6.2.3. Configuration commands
NAME
Access
(R/W)
Possible value on the serial
port of the unit
Comments
CONF.10M.OPE R/W "AUTO or "MANU"
Indicates the operating mode of the external
10 MHz input
CONF.AGC.ATT R/W
[0…32000]
Attack in dB/s
CONF.AGC.DRIVE R/W
[-320,00…320.00]
Drive applied before the AGC
CONF.AGC.REL R/W
[0…50,00]
Release in dB/s
CONF.AGC.STATE R/W
ON/OFF
Enables/disables the AGC function on
Line1, Line2 and Player
CONF.AGC.THR R/W
[-70,00…0]
Sets the non-triggering threshold in dB
CONF.AMB.MAX R/W [0..999]
Sets the triggering threshold for the ambient
temperature alarm
CONF.CROSSFADE R/W 0 to 25.5 Crossfade between channels (in seconds)
CONF.DEV.AUDIO R/W 0…150 Sets the audio excursion
CONF.DEV.CLIP R/W 0 to 200
Set the excursion clipping ; +128 = disabled
limitation
CONF.DEV.LIMIT R/W 0 to 200
Set the MPX excursion limitation; +128 =
disabled limitation
CONF.DEV.MPX R/W 00000 à 150.00 Sets the MPX excursion
CONF.DEV.MPXPWR R/W -12.7…12.7
Set the MPX power limitation; +128 =
disabled limitation
CONF.DEV.PILOT R/W 0 to 25.5 Sets the pilot excursion
CONF.DEV.RDS R/W 0 to 25.5 Sets the RDS excursion
CONF.DEV.SCA R/W 0 to 25.5 Sets the SCA excursion
CONF.DRIVE.LIMIT
R/W 0 to 25.5
Drive value of the FM limiter in dB
CONF.HEAT.MAX R/W [0..125]
Sets the triggering threshold for the radiator
1 temperature alarm
CONF.MODE R "LOCAL" or "REMOTE" Indicates the mode, local or remote
CONF.PHASE.PILOT R/W -180..+180 Sets the pilot phase
CONF.PHASE.RDS R/W -180..+180 Sets the RDS phase
CONF.RF R/W ON/OFF Enables/disables the RF
CONF.SBY R "ON" or "OFF"
Indicates if the transmitter is in standby
mode
CONF.STATE.CLIP R/W ON/OFF Enables/disables the Hard Clipper
CONF.STATE.LIMIT R/W ON/OFF Enables/disables the FM limiter
CONF.STATE.MPXPWR R/W ON/OFF Enables/disables the MPX Power limiter