8.2.2. Remote control function pinout
Function Remote Control Input name Common
STANDBY OFF RC1 OPT1A(20) RC_COMMUN(24)
STANDBY ON RC2 OPT2A(8) RC_COMMUN(24)
RF ON RC3 CONF1(21) RC_COMMUN(24)
RF OFF RC4 CONF2(9) RC_COMMUN(24)
TA ON RC5 CONF3(22) RC_COMMUN(24)
TA OFF RC6 CONF4(10) RC_COMMUN(24)
DSN MAIN RC7 CONF5(23) RC_COMMUN(24)
DSN ALT RC8 CONF6(11) RC_COMMUN(24)
Numbers in parenthesis indicated the pin number on the DB25 connector.
8.2.3. Remote monitoring function pinout
Event Remote Monitoring Output name Common
LOCAL RM1 REL1_RT(1) REL1_C(14)
FAULT RM2 REL2_RT(2) REL2_C(15)
WARNING RM3 REL3_RT(3) REL3_C(16)
RF (ON/OFF) RM4 REL4_RT(4) REL4_C(17)
ON RM5 REL5_T(5) REL5_C(6)
OFF RM6 REL5_R(5) REL5_C(6)
VSWR RM7 REL6_RT(6) REL6_C(7)
Numbers in parenthesis indicated the pin number on the DB25 connector.
A closed link indicates valid information when configuration is as in the following table.
Default jumper position:
Relay
Positions Contacts
REL_1RT
JUMP2[1 ;2] NO
REL2_RT
JUMP3[1 ;2] NO
REL3_RT
JUMP5[1 ;2] NO
REL4_RT
JUMP1[1 ;2] NO
REL6_RT
JUMP4[1 ;2] NO
Jumpers from 1 to 5 (JUMP1 to JUMP5): select the NO or NC contact of the relays.
When switching to local mode (relay 1), all other relays are disabled.