10 Troubleshooting
Problem: DATA indicator does not flash or illuminate, even though a
valid command was sent.
Possible causes:
• Command was not addressed to the PIP.
• Network configuration cable is disconnected or broken.
To assist with troubleshooting, an option that forces the data indicator
to remain lit is available through the software. Some Crown amplifiers
also have a data indicator on their front panels. In these cases this indi-
cator will light simultaneously with the PIP's data indicator.
Problem: Green Preset indicator is flashing, or is not flashing.
Possible cause: This is not a problem. This indicator signals the
number of the current preset, if active, by flashing a series of flashes
equal to the current preset number. A preset is considered “active” if
the PIP settings match those in the selected preset. If a change is made
to any setting then the preset is considered “inactive,” and the indicator
stops flashing.
PIP-USP3/CN ONLY
Problem: Green LINK indicator is not lit.
Possible cause: Ethernet link is not present. Check Ethernet con-
nections to switch. PIP-USP3/CN is not connected to100Base-T
switch.
PIP-USP3/CN ONLY
Problem: Both right indicators flash yellow in unison to report a fatal
error.
Possible cause: An unexpected condition within the CobraNet inter-
face has been detected.