Product specifications

User information Doka heavy-duty supporting system SL-1
19999759002 - 06/2008 Ü
The Formwork Experts
Butt-strap join
By combining packing plates with thicknesses of
2, 3 and 4 mm, closures can be made in a 1 mm
increment-grid.
Permitted internal forces
N
f
= actual normal force in the join
A System beam SL-1
B Connection splice plate SL-1
C Screw set for Connection splice plate SL-1
D 2 hexagonal bolts M22x120 8.8 and 4 hexagon nuts M22 8
(included with Item C)
F Packing plate SL-1
Important note:
The screws (D) are only for transferring
the shear force. Owing to the tolerances,
they must be fitted with a play of
a ... min. 5 mm. Secure the connection by
countering with a second nut.
a ... min. 5 mm
Under load, a gap of up to 5 mm and/or
up to 2% buckling may occur between the
screws and the drilled holes, due to pro-
duction-related tolerances.
These tolerances can be equalised by
installing packing plates.
Packing plates must be fitted wherever
joins are subjected to bending stress.
TR585-201-01
A
C
B
D
F
9759-247-01
a
A
D
F
Permitted moment M [kNm]
Permitted shear force Q [kN]
G N
f
= 0 kN
H N
f
= 100 kN
I N
f
= 200 kN
J N
f
= 300 kN
K N
f
= 400 kN
L N
f
= 600 kN
G
H
I
J
K
L
200
180
160
140
120
100
80
60
40
20
0
020
40
60
80
100 120
140
160
180
220
200
240
260
9759-110a
87
221
9759-103-01
M
N
M
Q
Q
N