Specifications

one is aboard. Aux (electric) Heat Mode is available for TW
systems.
SMXht offers the same outstanding a/c system protection as
our other SMXII series controls. Line voltage and refrigerant
high and low pressure switches are constantly monitored. If
a problem is detected, the system will shut down and display
a fault code on the keypad/display. A nonvolatile memory
retains current operation mode and all programmable
settings when power is turned off or lost, such as when
changing from generator to dock power. The programmable
compressor time delay function will prevent multiple units
from starting at the same time when power is restored.
Many of the factory settings can be changed to allow
the user to fine-tune the system to best match the boat
and personal preferences. (See the list of programmable
functions.) A complete system consists of a power/logic
module (the SMX II-HV), keypad/display, CXP connecting
cable and a TSEP temperature sensor.
3-47/64" (95mm)
Mounting Holes
3-7/16" (87.31mm)
Cutout
2-1/8"
(53.98mm
Cutout)
2-3/64
(51.99mm)
Mounting Holes
4-27/32" (123.22mm)
3-17/64" (82.81mm)
Front view shown here with Vimar Ideal bezel.
Gewiss Playbus bezels are also availalbe. All
bezels are sold separately.
3/4"
(19mm)
Side view
(no bezel)
4-25/64" (111.60mm)
2-13/16" (71.50mm)
Rear view showing location
of CXP cable connection
Clip-on wings are for use with Vimar
Ideal bezels only. Gewiss Playbus
bezels do not require these clips.
DOMETIC CORPORATION, ENVIRONMENTAL DIVISION
2000 N. Andrews Ave. Ext. l Pompano Beach, FL 33069 USA l 954-973-2477 l Fax 954-979-4414
P.O. Box 15299 l Richmond, VA 23227 USA l 804-746-1313 l Fax 804-746-7248
www.DometicEnviro.com l sales@DometicEnviro.com
United States & Canada Service Only:
8:00 AM to 5:00 PM Eastern Time l Marine Air AC Products: 954-973-2477
Cruisair AC Products: 804-746-1313
24/7 AC SERVICE HOTLINE: 5:00PM to 8:00 AM: 888-440-4494
International Sales & Service:
Europe & the Middle East: Call +44(0)870-330-6101
For all other areas visit our website to nd your nearest distributor.
L–2376 Rev. 20080829
Dealer:
Environmentally
Responsible
Programmable Functions
Backlight Mode
Select DX or TW power/logic board
Fahrenheit/Celsius Display
DX Compressor Time Delay
Fan Response Differential
Low and High Fan Speed
AC Line Voltage Calibration
Temperature Calibration
HU Dehumidication
High to Low Speed Adjustment
Software Version
Software Revision
LED Segment Test
Select SMXII power/logic board.
(SMX Net will be supported in the
future.)
Ship-Wide
Network Capable
52 Controls