Operating instructions
to fill the tanks. Once completed, you will notice two clear pipes also 
underneath the caravan. These clear pipes are your overflow 
indicators. You can now switch the valves off and continue to use main 
pressure once the tanks are full. 
Ensure that these valves are switched off when operating the water 
pump otherwise the pump may draw air into the system. 
!
!
!
!
!
IMPORTANT. 
When connected to mains water pressure, ensure that the pump 
isolation switch is turned off – OTHERWISE you will continue to pump 
water from your water tanks and NOT mains water. 
BLEEDING THE WATER SYSTEM 
If you discover that there is minimal water flow when operating under 
the water pump or there is obvious indicating that air is in your water 
pipes. You need to bleed the system.  
Procedure: Open all taps (Ensuite – vanity – shower – kitchen – A frame 
tap) 
Turn on water pump. Proceed to A frame tap....once water is flowing 
normally turn tap off....follow same procedure with kitchen tap – 
vanity and shower. 
The system has now been bled of any air pockets. 
!  3
Switch valves
Main Pressure Connection