Datasheet

DataSheet
Panel Mount
CW24 Series
Ratings from 10A to 125A @ 24-280VAC
SCR Output for heavy industrial loads
LED Status Indicator
UL/CSA/TUV Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
For Generation 3 datasheet click here
AC or DC control and Universal
AC/DC control
EMC Compliant to Level 3
Epoxy Free Design
Removable IP20 touch-safe cover
DBC substrate for superior thermal
performance
PRODUCT SELECTION
Control Voltage 10A 25A 50A 90A 125A
3-32 VDC CWD2410 CWD2425 CWD2450 CWD2490 CWD24125
90-280 VAC CWA2410 CWA2425 CWA2450 CWA2490 CWA24125
18-36 VAC CWA2410E CWA2425E CWA2450E CWA2490E CWA24125E
20-48 VDC/20-280 VAC CWU2410 CWU2425 CWU2450 CWU2490 CWU24125
AVAILABLE OPTIONS
Not all part number conbinations are available.
Contact Crydom Technical Support for information on
the availability of a specific part number.
*
Required for valid part number
For options only and not required for valid part number
Operating
Voltage
24: 24-280 VAC
Control Voltage
D: 3-32 VDC
U: 20-48 VDC or 20-280 VAC
A: 90-280 VAC
AxxxxE: 18-36 VAC
Thermal Pad
Blank: Not Included
H: Included
Series
Rated Load Current
10: 10 Amps
25: 25 Amps
50: 50 Amps
90: 90 Amps
125: 125 Amps
Switching Type
Blank: Zero Voltage Turn-On
-10: Instantaneous Turn-On
Overvoltage Protection
Blank: Not Included
P: Included (3)
1024CW D E
-10P H
OUTPUT SPECIFICATIONS
(1)
Description 90A25A
Operating Voltage (47-440Hz) [Vrms] 24-280 24-280
Transient Voltage [Vpk] 600 600
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 1 1
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec) 500 500
Maximum Load Current [Arms]
(2) 25 90
Minimum Load Current [mArms] 150 250
Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 570/600 1290/1350
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.3 1.3
Thermal Resistance Junction to Case (Rjc) [°C/W] 0.3 0.16
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 1620/1500 8320/7560
125A50A10A
24-280 24-280 24-280
600 600 600
1 1 1
500 500 500
10 50 125
150 150 250
380/400 810/850 1900/2000
1.3 1.3 1.25
0.35 0.2 0.11
720/660 3280/3000 18000/16600
Minimum Power Factor (at Maximum load) (3) 0.5 0.5
0.5 0.5 0.5
HP Rating UL 508/IEC60947 [-10 Option][HP (KW)]: 120 VAC 1 (0.74) 3 (2.24)
0.5 (0.37) 2 (1.5) 5 (3.37)
HP Rating UL 508/IEC60947 [-10 Option][HP (KW)]: 240 VAC 3 (2.2) 7.5 (5.6)
1.5 (1.1) 5 (3.73) 10 (7.5)
HP Rating UL 508/IEC60947 [HP (KW)]: 120 VAC 0.75 (0.56) 2 (1.5)
0.5 (0.37) 1 (0.74) 3 (2.24)
HP Rating UL 508/IEC60947 [HP (KW)]: 240 VAC 2 (1.5) 5 (3.73)
1.5 (1.1) 3 (2.2) 7.5 (5.6)
INPUT SPECIFICATIONS
(1)
Description CWD
Control Voltage Range 3-32 VDC
Maximum Reverse Voltage -32 VDC
Minimum Turn-On Voltage 3 VDC (4)
Minimum Turn-Off Voltage 1 VDC
Minimum Input Current (for on-state) 10 mA
Maximum Input Current 15 mA
Nominal Input Impedance Current Regulated
Maximum Turn-On Time [msec] 1/2 Cycle (6)
Maximum Turn-Off Time [msec] 1/2 Cycle
CWA
90-280 VAC (5)
-
90 VAC
10 VAC
6 mA
10 mA
Current Regulated
20
30
CWAxxxxE
18-36 VAC
-
18 VAC
4 VAC
13 mA
15 mA
Current Regulated
20
30
CWU
20-48 VDC/ 20-280VAC
-
19 VDC/VAC
5 VDC/VAC
7/13 mA
11/9 mA
Current Regulated
20
30
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Crydom Inc. Specifications subject to change without notice.

Summary of content (8 pages)