Installation Manual

Cryptera A/S SV/INT3520-2000-10 rev.B Page 15 of 22
Installation Manual
In any case, it is highly recommended to verify that the specific front panel material and
the intended mounting concept allows for a robust NFC communication at an early design
stage, before the final design is released for production.
5.2 Mounting Details
5.2.1 Protruding
The recommended mounting for front panels made of magnetic material. The NFC
Reader can be mounted with full protrusion using the supplied gasket and standard studs
or bolts.
Figure 7 Protruding
5.2.1.1 Cut-out
The following figure shows the cut-out and mounting details for a full protrusion
installation.
Figure 8 Cut-out and mounting details
5.2.1.2 Gasket
The supplied gasket must be used, in order to obtain a watertight (IP65) installation and
avoid water in the internal parts of the NFC Reader and the target equipment.