Instruction manual
30
www.cs-instruments.com
The measuring instrument DS 300 mobile 
enables the analysis of compressed air 
stations. Up to 4 clamp-on ammeters 
measure the current consumption of every 
single compressor. Optionally also 
4 pressure sensors, temperatrure sensors or 
any other analogue sensors can be 
connected. 
In addition, the DS 300 mobile measures 
the discharged compressed air in m³/h, m³ 
and the dew point temperature in °Ctd at 
the same time.
The integrated data logger stores up to 
1 million measured values.
The CS analysis software enables the 
graphical and statistical evaluation of the 
stored data at the PC. 
From the stored current values it is 
possible to calculate the costs in € for 
the energy consumption (kWh) as well 
as the load and idle times of every single 
compressor including switch-on/switch-off 
cycles.
The costs per m³ and the total costs per 
year in € are calculated from the actually 
consumed quantity of compressed air. 
A special leakage calculation determines 
the cost share of the leakages in 
comparison to the total costs in €.
For documentation of the measured 
values the user gets a DIN A 4 graphics 
printout for each compressor in a day view 
and in a week view at the touch of a 
button.
The additional printout with the statistical 
values contains all necessary data for a 
complete analysis of the compressor stations 
(see page 32).
Complex Excel® calculations and the issuing 
of reports are no longer necessary. Each ser-
vice company can issue a report for the end 
customer with their own logo and additional 
information.
Compressed air analyzer DS 300 mobile 
Energy analysis – consumption measurement – leakage calculations at 
compressed air systems
Consumption
Dew point
Pressure
Current
Current
Current
Consumption