Instruction manual
34
www.cs-instruments.com
Consumption
What are the advantages of the 
consumption measuring technology 
of CS Instruments?
Inner diameter of pipe  VA 400 Standard  VA 400 Max.  VA 400 HighSpeed
(92.7 m/s)  (185.0 m/s)  (224.0 m/s)
Inch  mm    Meas. ranges  Meas. ranges  Meas. ranges
      from ... to  from ... to  from ... to
1/2”  16.1  DN 15  2.5...760 l/min  3.5...1516 l/min  6.0...1836 l/min
3/4”  21.7  DN 20  0.3...89 m
3
/h 0.4...178 m
3
/h 0.7...215 m
3
/h
1”  27.3  DN 25  0.5...148 m
3
/h 0.6...295 m
3
/h 1.1...357 m
3
/h
1 1/4”  36.0  DN 32  0.9...280 m
3
/h 1.2...531 m
3
/h 2.5...644 m
3
/h
1 1/2”  41.8  DN 40  1.2...365 m
3
/h 1.5...728 m
3
/h 3.0...882 m
3
/h
2”  53.1  DN 50  2...600 m
3
/h 2.5...1198 m
3
/h 4.6...1450 m
3
/h
2 1/2”  71.1  DN 65  3.5...1096 m
3
/h 5...2187 m
3
/h 7...2648 m
3
/h
3”  84.9  DN 80  5...1570 m
3
/h 7...3133 m
3
/h 12...3794 m
3
/h
4” 110.0 DN 100 9...2645 m
3
/h 12...5279 m
3
/h 16...6391 m
3
/h
5”  133.7  DN 125  13...3912 m
3
/h 18...7808 m
3
/h 24...9453 m
3
/h
6”  159.3  DN 150  18...5560 m
3
/h 25...11097 m
3
h 43...13436 m
3
/h
8”  200.0  DN 200  26...8786 m
3
/h 33...17533 m
3
/h 50...21230 m
3
/h
10”  250.0  DN 250  40...13744 m
3
h 52...27429 m
3
/h 80...33211 m
3
/h
12”  300.0  DN 300  60...19815 m
3
/h 80...39544 m
3
/h 100...47881 m
3
/h
Drilling under pressure
A 
Screw neck
B 
Spot drilling collar
  Even under pressure, the consumption 
probe VA 400 is mounted by means of 
a standard 1/2" ball valve. During 
mounting and dismounting the safety 
ring avoids an uncontrolled ejection of 
the probe which may be caused by the 
operating pressure. 
  For the mounting into different pipe 
diameters VA 400 is available in the 
following probe lengths: 120, 160, 220, 
300, 400 mm.
  So the consumption probes are 
being mounted into existing 
pipelines with inner diameters of 1/2" 
upwards. 
  The exact positioning of the sensor in 
the middle of the pipe is granted by 
means of the engraved depth scale. 
The maximum mounting depth 
corresponds with the respective 
probe length. Example: VA 400 with 
probe length 220 mm has a maximum
mounting depth of 220 mm.
 If there is no suitable measuring site 
with a 1/2" ball valve present there are 
two simple possibilities to set up a 
measuring point:
  A  Weld on a 1/2” screw neck and 
    screw on a 1/2” ball valve. 
  B  Mount spot drilling collar incl. ball 
 valve (see accessories).
  By means of the drilling jig it is possible 
to drill under pressure through the 1/2" 
ball valve into the existing pipeline. 
The drilling chips are collected in a 
filter. Then the probe can be mounted 
as described under point A.
  Due to the large measuring range of 
the probe even extreme requirements 
to the consumption measurement 
(high volume flow in small pipe 
diameters) can be met. The measuring 
range is depending on the pipe 
diameter - see table on the right hand 
side.
1/2” ball valve
closed
1/2” 
mounting
thread 
engraved
depth scale
safety ring
mounting depth 
= x + y
d
A
 =  outer diameter
x =
y
쑿
쑼
쑼
쑿쑿
쑼
x
d
A
d
A
2
Flow measuring ranges VA 400 for compressed air (ISO 1217: 1000 mbar, 20°C)