Instruction manual
www.cs-instruments.com
39
Consumption
Flow station DS 300
with direction indication in one direction
By connecting the flow direction switch 
VA 409 to the flow station DS 300 only the 
consumption in one direction is measured. 
So it is guaranteed that the back-flowing 
compressed air is not counted twice. 
Special features
 precise consumption measurement in
 one direction
 when doing the cost calculation of the 
  compressed air it is avoided that back-
  flowing compressed air is counted twice
Flow station DS 300
with flow direction indication in both directions
For this reason two flow stations DS 300 
are used for precise consumption 
measurement of both flow directions.
Special features
 precise consumption measurement
  in both directions
 separate indication of the actual
  consumption (m³/h resp. m³/min etc…) 
  separate summing of the total   
  consumption (m³ resp. l)
 forwarding of the analogue output and 
  of the pulse output for the respective 
 flow direction
In case the flow direction switch VA 409 
indicates the flow direction and forwards 
this information to the flow station DS 300.
Each of both flow stations DS 300 
exclusively measures the flow in one 
direction. The flow direction switch VA 409 
is mounted in the middle between both 
flow stations in order to avoid flow 
turbulences.










