Instruction manual
The telescope bar helps 
locating leakages in 
pipelines up to a height 
of 6 m
Focus tube with focus tip 
avoids influence by ambient 
noise and enables precise
locating of leakages
Holding device of LD 300 
at the telescope bar
Annual energy costs caused by leakages
Hole    Loss in air   Energy loss   Costs p.a. 
Ø  at 6 bar  at 12 bar  at 6 bar  at 12 bar  at 6 bar  at 12 bar
(mm) (l/s)  (l/s)  kW/h  kW/h  €  €
1 1.2 1.8 0.3 1.0  144 480
3  11.1  20.8  3.1  12.7  1.488 6.096
5  30.9  58.5  8.3  33.7  3.984 16.176
10  123.8  235.2  33.0  132.0  15.840 63.360
Source: www.druckluft.effizient.de (*) kW x 0.06 € x 8.000 Bh/a
LD 300 leak detector
If gases escape through leaks ultrasonic noises are generated. By means of the LD 300 
leakages can be detected in the ultrasonic range even from distances of several meters. 
LD 300 transforms the inaudible signals into a frequency which can be 
identified by means of the provided sound-proof headset. In depressurized 
systems an ultrasonic tone generator can be used of which the signal travels through 
smallest openings.
Leak detection in:
  Compressed air lines, gas, vapour and vacuum plants
  Refrigerating plants
  Door seals
Applications:
Sound-proof headset enables
leak detection in extremely 
noisy environments
48
www.cs-instruments.com
Leakage