D-31353-2011 D-32163-2011 D-23543-2010 ST-9207-2007 Dräger Gas Detection Dräger: Technology for Life®
Inside front cover BLANK
DRÄGER GAS DETECTION | 02 Dräger Gas Detection TABLE OF CONTENTS ST-831-2003 Dräger X-zone 5000 Dräger X-am 2000 Dräger X-am 5000 Dräger X-am 5600 Dräger X-am 3000 Dräger X-am 7000 Dräger Pac 7000 Dräger Pac 3500/5500 Dräger-Sensors®, XXS and PID Sensors Dräger E-Cal Systems Calibration Gases Dräger Software Dräger Support Material Dräger Training Software Dräger CMS Analyzer Dräger CMS Chips Dräger accuro® Pump and Dräger X-act® 5000 Short Term Dräger-Tubes® Dräger Emergency Response Kits TWA Measureme
03 | DRÄGER GAS DETECTION Area monitoring without limits. Dräger X-zone® 5000 D-23602-2009 Area monitoring without limits – the Dräger X-zone 5000. In combination with the Dräger X-am 5000 or X-am 5600, the X-zone 5000 reliably monitors for up to six hazardous gases and warns at preset levels. This easily transportable, robust and water-proof unit extends mobile gas detection technology to a unique system with many applications.
D-32163-2011 DRÄGER GAS DETECTION TECHNICAL DATA D-31351-2011 Dimensions (W x H x D) Weight Approvals D-27601-2009 Area monitoring Dräger X-zone 5000 complements the Dräger personal gas measuring devices X-am 5000 and X-am 5600. Wireless fence line Up to 25 Dräger X-zone 5000 automatically interconnect to form a wireless fence line. 16.2 x 11.4 x 11.4 inch (490 x 300 x 300 mm) 15 lbs. (7 kg) (12 Ah battery), 22 lbs.
05 | DRÄGER GAS DETECTION The Dräger X-am 2000 represents a new generation of personal gas detectors. DRÄGER X-AM 2000 The Dräger X-am 2000 represents a new generation of personal gas detectors which have been specially designed for personal monitoring. These gas detectors reliably measure combustible gases and vapors, as well as O2, CO and H2S. Their ergonomic design, mobile phone dimensions and light weight make them the perfect companion in your daily work.
| 06 ST-7317-2005 ST-7202-2005 DRÄGER GAS DETECTION TECHNICAL DATA Gases Detected Dimensions Weight Approvals Combustible Gases, O2, CO and H2S. 1.85 x 5.08 x 1.22 inch (7 x 129 x 31 mm) 7.8 oz (220 g) ATEX II 2G EEx ia d IIC T4/T3 - I M2 EEx ia d I UL Cl. I Div. 1 Group A,B,C,D - Cl. II E,F,G T.-Code T4/T3 CSA Cl. I Div. 1 Group A,B,C,D T.
DRÄGER GAS DETECTION D-27592-2009 07 | Dräger X-am 5000 DRÄGER X-AM 5000 The smallest gas detection instrument for up to 5 gases. The Dräger X-am 5000 belongs to a new generation of gas detectors, developed especially for personal monitoring applications. This 1 to 5-gas detector reliably measures combustible gases and vapors as well as oxygen and harmful concentrations of CO, H2S, CO2, Cl2, HCN, O3, COCl2, NH3, NO2, PH3, SO2, amines, odorants and organic vapors.
DRÄGER GAS DETECTION TECHNICAL DATA Dimensions (W x H x D Weight Ambient conditions Alarms Battery options Operating times Charging times Data logger Pump operation Approvals 1.85 x 5.08 x 1.22 inch (47 x 129 x 31 mm) Approximately 7.8 oz. (220 g) Temperature -4 to +122 °F, -20 to +50 °C, Pressure 700 to 1300 mbar, 20.7 to 38.4 inch Hg Humidity 10 to 95% RH Visual 180° Audible Multi-tone >90 dB at 30 cm, 1 ft.
DRÄGER GAS DETECTION ST-16008-2008 09 | Innovation in the palm of your hand. Dräger X-am 5600 — Unprecedented protection from the market’s smallest, infrared-capable, six-gas personal monitor. PRODUCTIVIT Y BIG TIME As the smallest device of its type in the industry it is much less obtrusive on the user allowing him to focus on the task at hand. In addition the X-am 5600 can measure up to 6 gases at one time reducing the need for additional instruments.
DRÄGER GAS DETECTION | 10 Innovation in the palm of your hand.
11 | DRÄGER GAS DETECTION Innovative Measuring ST-3493-2004 ST-482-2007 ST-6048-2004 for combustible gases Dräger X-am 3000 The Dräger X-am 3000 Monitor is a small and innovative measuring device for Combustible Gases, O2, CO and H2S in industrial gas detection applications. Go about your job confidently knowing that the Dräger X-am 3000 will measure and alert you to dangerous gases and vapors. The most convenient feature of the Dräger X-am 3000 is the optional built-in remote sample pump.
ST-127-2004 DRÄGER GAS DETECTION Dräger X-am® 3000 Designed for durability and reliability—and single-handed detection of up to 6 gases T EC H N I C A L DATA Gases Detected Dimension Weight Approvals Combustible Gases, O2, CO and H2S. 3.5 x 5.5 x 2.1 inch (89 x 140 x 55 mm) 19.4 oz.
13 | DRÄGER GAS DETECTION Dräger X-am 7000: Multiple gas measurement capabilities in one compact package. DRÄGER X-AM 7000 ST-2770-2003 ST-2660-2003 ST-2642-2003 The Dräger X-am 7000 Monitor combines electrochemical (EC), catalytic oxidation (CAT), photo ionization (PID) and infrared (IR) sensing technology for a total of up to 5 sensors. You can choose from over 25 different electrochemical Dräger-Sensors®, 3 different catalytic sensors, a PID Sensor and 3 different IR sensors.
ST-9382-2007 DRÄGER GAS DETECTION T EC H N I C A L DATA Smart PID Sensors Smart EC Sensors Smart IR Sensors Smart CAT Sensors Size Weight Approvals VOC’s O2, H2S, CO, CL2, NH3, NO2, SO2, HCN, CO2, NO, H2, H2S-HC, CO-HC, PH3-HC, H2-HC, ClO2, Organic Vapors, Hydrides, Amines, Mercaptans, Combustible Gases (Ex) or Carbon Dioxide (CO2) Standard 100 %LEL Combustible Gas or 100% Vol. CH4 5.9 x 5.5 x 2.9 inch (150 x 140 x 75 mm) 2.4 lbs. (1.
15 | DRÄGER GAS DETECTION ACTUAL SIZE SHOWN ST-1758-2005 Pac 7000: The innovative single gas instrument with reliable monitoring of ambient air. DRÄGER PAC 7000 MONITOR The innovative Dräger Pac® 7000 is small and robust, ergonomic and intuitive, economic and powerful – the Dräger Pac 7000 is an impressive single gas monitor equipped with a wide range of functions.
DRÄGER GAS DETECTION T EC H N I C A L DATA Gases Measured H2S, CO, O2 and other toxics Dimensions 2.5 x 3.3 x 1.0 inch (64 x 84 x 25 mm) Weight 3.8 oz.
17 | DRÄGER GAS DETECTION Pac 3500/5000 Monitors: Accurate, quick, reliable detection. DRÄGER PAC 3500/5500 MONITORS SMALL AND ROBUST HOUSING HIGHLY VISIBLE DISPLAY Small in size and light in weight, the Dräger Pac® 3500 and the Dräger Pac® 5500 were developed with the needs of industrial users and applications in mind. The instruments provide easy, singlehanded operation, even when wearing gloves, and is designed to withstand the toughest environments.
ST-5608-2004 ST-5064-2005 DRÄGER GAS DETECTION DRÄGER X-AM PAC ® 3500/5500 MONITOR O R D E R I N FO R M AT I O N Description Dräger Pac® 3500 CO Dräger Pac® 3500 H2S Dräger Pac® 3500 H2S w/ yellow keypad overlay Dräger Pac® 3500 O2 Dräger Pac® 3500 O2 w/ blue keypad overlay Dräger Pac® 5500 CO Dräger Pac® 5500 H2S Dräger Pac® 5500 H2S w/ yellow keypad overlay Dräger Pac® 5500 O2 Dräger Pac® 5500 O2 w/ blue keypad overlay Measuring Range 0 – 500 ppm 0 – 100 ppm 0 – 100 ppm Default Alarm Threshold A1/A2
DRÄGER GAS DETECTION ST-378-2007 19 | ELECTROCHEMICAL (EC) SENSORS DRÄGER-SENSOR® XS-R DRÄGER-SENSOR® XS-2 The XS-R sensors offer the longest warranties and require the least maintenance of any sensor in the industry. The Dräger-Sensors® XS-R for CO, H2S and O2 are covered by an unequalled 5-Year Warranty! Yes, even our O2 sensor which continuously detects oxygen for a period of 5 years! This is far better than what other manufacturers can offer.
DRÄGER GAS DETECTION D R ÄG E R X S TOX I C G A S A N D VA P O R S E N S O R S E L EC T I O N Gas Sensor (XXS) Sensor (XS) Range Resolution 1-Chloro-2,3-epoxypropane Acetaldehyde Acrylonitrile Ammonia Arsine Bromine Butadiene Butyl Mercaptan Carbon Dioxide Carbon Monoxide (2 Year Warranty) Carbon Monoxide (3 Year Warranty) Carbon Monoxide (5 Year Warranty) Carbon Monoxide (High Concentration) Chlorine Chlorine Dioxide Diborane Diethylamine Diethyl Ether Dimethylamine Dimethyl Sulfide Dimethyl Disulfi
21 | DRÄGER GAS DETECTION Easy Calibration while saving time and money. DRÄGER E-CAL SYSTEMS The Dräger E-Cal system makes calibrating your Dräger gas detection instruments easy while saving time and money. The Dräger E-Cal system automatically calibrates up to 10 gas monitors and documents the entire process making it ideal for ISO-9001 compliance. - Simultaneous automatic calibration of up to 10 instruments at once saving time and money.
ST-104-2002 DRÄGER GAS DETECTION T EC H N I C A L DATA Dimensions Master Station (l x w x h) 12.3 x 12.1 x 2.5 in (295 x 290 x 60 mm) Dräger Pac X000 Module (l x w x h) 12.3 x 10.0 x 2.5 in (295 x 240 x 60 mm) Dräger X-am 1/2/5000 Module (l x w x h) 12.3 x 5.6 x 2.5 in (295 x 135 x 60 mm) Dräger X-am 3000 Module (l x w x h) 12.3 x 10.0 x 2.5 in (295 x 240 x 60 mm) Dräger X-am 7000 Module (l x w x h) 12.3 x 10.0 x 2.
23 | DRÄGER GAS DETECTION Dräger’s Full Range of Calibration Gases All gas detection sensors require periodic calibration or bump testing. Dräger offers a full range of calibration gas mixtures in various concentrations and related supplies. TOX I C G A S E S The following gases are most commonly requested and recommended calibration gases for TWA measurements. Other gases and concentrations are available, contact Dräger for the full selection of calibration gases.
DRÄGER GAS DETECTION Calibrate, configure and document Document gas and vapor exposures measured with Dräger instruments equipped with internal data loggers. Quickly and easily determine TWA and STEL exposures. Create graphs and spreadsheets from this data for documentation and reporting purposes with included graphical and tabular report generators. Dräger Gas-Vision® is also a complete management tool that will manage the stored exposure data for you.
25 | DRÄGER GAS DETECTION Dräger Support Materials GAS DETECTION SELECTION GUIDE This booklet lists the most common industrial chemicals and whether there is a Dräger-Tube®, Dräger CMS-Chip, and/or Dräger-Sensor® available for detecting this substance. The Selection Guide also includes a list of the Dräger Detection products available with measuring ranges and order information. Contact our Customer Service Department for a free copy of this valuable field guide for health and safety professionals.
D-20750-2009 DRÄGER GAS DETECTION Dräger-Training and Training Software Even though Dräger equipment is simple to operate, the new equipment must be understood by all who use them. To make your job easier, Dräger Safety has created training tools in MS Power Point to aid in the implementation of your new equipment. These programs contain operating training modules, a competency test, helpful maintenance tips, and a guide to accessories and options.
27 | DRÄGER GAS DETECTION Accurate gas measurements made easier. DRÄGER CMS ANALYZER Dräger CMS does not require gas calibration. All measurement and calibration information is stored on a bar code on the CMS Chip. An electronic leak check is performed before each measurement so you are assured of accurate indications every time. Operating on 4 “AA” cells, the Dräger CMS will deliver about 100 measurements per battery change.
ST-840-2004 DRÄGER GAS DETECTION S P EC I F I C AT I O N S Dimensions 4.1 x 8.5 x 2.5 inch (105 x 215 x 65 mm) Weight 25.6 oz. (730 g) Operational Temperature 32 - 104 °F (0 - 40 °C) Ingress Protection IP-54, protected against dust and water Data Capacity Stores up to 50 measurements Power Supply 4 x 1.
DRÄGER GAS DETECTION Cancellation Pins Measurement Capillary Sampling Septum Information Barcode ST-9318-2007 29 | Direction of Insertion into CMS Analyzer Shown Actual Size Dräger CMS - accurate, versatile, easy to use for chemical specific measurements. DRÄGER CMS ® CHIP The Dräger CMS Chip consists of 10 measurement capillaries filled with substance-specific reagent systems. The gas type, part number and batch number are printed on the chip.
DRÄGER GAS DETECTION Description Acetic Acid Acetone Ammonia Ammonia Ammonia Ammonia Benzene Benzene Benzene Benzene Butadiene Carbon Dioxide Carbon Dioxide Carbon Dioxide Carbon Monoxide Chlorine Ethanol Ethylene Oxide Formaldehyde Hydrochloric Acid Hydrochloric Acid Hydrocyanic Acid Hydrogen Peroxide Hydrogen Sulphide Hydrogen Sulphide Hydrogen Sulphide Hydrogen Sulphide Iso-Propanol Mercaptan Methanol Methylene Chloride MTBE Nitrogen Dioxide Nitrous Gases Nitrous Gases Oxygen Ozone Perchloroethylene Pet
DRÄGER GAS DETECTION D-8775-2009 D-23543-2010 31 | Dräger’s leading edge technology puts us on the forefront of colorimetric detector tubes. DRÄGER ACCURO ® PUMP AND DRÄGER X-ACT ® 5000 The world has relied on Dräger-Tubes® more than any other gas and vapor measurement device to tell them when the air is safe to breathe, to identify an unknown hazard, or to check on process gases.
DRÄGER GAS DETECTION D R ÄG E R AC C U R O ® P U M P O R D E R I N FO R M AT I O N Dräger accuro® Pump 64 00 000 Soft-Sided accuro® Pump Kit 40 53 473 Hard-Sided accuro® Pump Kit 40 56 443 Extension Hose, 3 meter 64 00 077 Extension Hose, 10 meter 64 00 078 Extension Hose, 15 meter 64 00 079 Hot Air Probe CH 00 213 Tube Opener 7000 64 01 200 accuro® Pump and X-act® 5000 Pump are available for rental.
33 | DRÄGER GAS DETECTION WHAT IS THE DRÄGER-TUBE® SYSTEM? Dräger-Tubes® are glass vials filled with a chemical reagent that reacts to a specific chemical or family of chemicals. With each stoke a calibrated 100 ml sample of air is drawn through the tube with the Dräger accuro® bellows pump. If the targeted chemical(s) is present the reagent in the tube changes color and the length of the color change typically indicates the measured concentration.
Dräger-Tube® Hydrogen Fluoride 0.5/a Measuring Range Part No. 0.5-90 ppm 81 Dräger-Tube® 03 251 Perchloroethylene 2/a 1-155-87 2-550-2007 ST-551-2007 DRÄGER GAS DETECTION Measuring Range Part No. 2-300 ppm 81 10-500 ppm CH 01 501 30 701 Hydrogen Peroxide 0.1/a 0.1-3 ppm 81 01 041 Perchloroethylene 10/b Hydrogen Sulfide 0.2/a 0.2-5 ppm 81 01 461 Petroleum Hydrocarbons 10/a 10-300 ppm (n-Octane) 81 01 691 Hydrogen Sulfide 0.2/b 0.
DRÄGER GAS DETECTION Dräger Emergency Response Kits ST-533-2007 35 | DRÄGER CMS EMERGENCY RESPONSE KIT Put the simplicity of the Dräger CMS to work for you in your emergency response procedures. The Dräger CMS Emergency Response Kit contains the Dräger CMS Analyzer, the appropriate accessories, and a selection of 10 different Chips for response to HazMat or other situations.
DRÄGER GAS DETECTION | 36 DRÄGER CLAN LAB SIMULTEST KIT The illegal manufacture of methamphetamine is a serious problem in North America. Dräger has developed a Simultest Set with detector tubes that quickly confirm the presence of chemicals commonly associated with three principal methods of methamphetamine production. This allows law enforcement and first responder personnel to make fast decisions on the need for respiratory protection.
37 | DRÄGER GAS DETECTION DRÄGER AEROTEST KITS Dräger-Tubes® are widely used to measure the quality of compressed breathing air, the purity of medical gases, contaminants in process gases, and impurities in technical gases. The Aerotest Kits facilitate these types of measurements by conditioning the pressurized sample to a level at which the Dräger-Tubes® can accurately operate.
DRÄGER GAS DETECTION | 38 DRAGER BIO-CHECK ALLERGEN CONTROL ORDER INFORMATION Drager Bio-Check Allergen Control (package of 5) 64 00 945 ST-167-2004-1000 The house dust mite is the most common cause of allergies. The Dräger-Bio-Check Allergen Control rapid-test allows the user to conduct an on-site analysis of house dust mite allergens. The table supplied with Dräger-Bio-Check Allergen Control groups the exposure levels into categories based on the scientific limit values for house dust allergens.
DRÄGER GAS DETECTION Air Current Measurement ST--6498 39 | DRÄGER FLOW CHECK Air current directions and flow rates are very important to gas detection. The visible plume of non-toxic, non-reactive smoke generated by the Dräger FlowCheck allows you to actually see the direction, dispersion, and relative speed of the air currents in an area. Knowing how the air is moving, you are better prepared to accurately measure gases. This smoke can also be used to detect air leaks around doorways or other fixtures.
DRÄGER GAS DETECTION Training and Support D-31376-2011 ST-40-2007 ST-13881-2010 for your Dräger protection and detection equipment. DrägerService Let DrägerService provide expert care for your respiratory protection equipment. Dräger has strategically located Service Centers across North America in Pittsburgh PA, Carson CA, Pasadena TX, Richmond BC, Dartmouth NS, Mississauga ON, Sudbury ON, Montreal PQ, Edmonton AB, and Queretaro, Mexico. Services are available at these locations or on-site.
DRÄGER GAS DETECTION T-3108-2004 41 | Dräger Swede Survival LIVE FIRE TRAINING IN WOOD-FUELED CLASS "A" CONTAINER SYSTEMS Dräger Swede Survival training systems offer firefighters the opportunity to observe fire behavior and the signs that lead to phenomena like a flashover. The training is being conducted according to proven procedures in order to create a safe and controlled training setting.
DRÄGER GAS DETECTION Dräger Fire Training Systems LIVE FIRE TRAINING IN PROPANE FUELED CLASS 'B' SYSTEMS Dräger's training systems provide ideal conditions for breathing apparatus users to experience physical and mental stress common to emergency situations in a controlled environment. Dräger Safety Systems is taking firefighting to a whole new level with the acquisition of Fire Training Systems (FTS).
DRÄGER GAS DETECTION D-31395-2011 ST-414-2007 43 | Respiratory Protection The Dräger X-plore® Series of filtering facepiece respirators sets the standard for comfort and adjustability. The unique tension adjuster allows a wearer to fine-tune the non-irritating fabric head strap to a proper fit. In addition, the strap provides a drop-down feature to comfortably hang around the neck when not needed.
ST-9207-2007 D-25038-2010 ST-16421-2008 DRÄGER GAS DETECTION Hard work in an industrial environment requires rugged and reliable equipment. The Dräger line of supplied air respirators confidently meets this challenge. Our modular airline respirator systems are based on the Dräger Panorama Nova mask that provides superior fit and comfort. The Type C Dräger SAR and constant flow Dräger PentAir® respirators are for working extended periods in non-IDLH environments.
45 | DRÄGER GAS DETECTION NOTES
Inside back cover BLANK
HEADQUARTERS: Dräger Safety AG & Co. KGaA Revalstrasse 1 23560 Lübeck, Germany REGIONAL OFFICES: CANADA Draeger Canada Ltd. 7555 Danbro Crescent Mississauga, Ontario L5N 6P9 Tel +1 905 821-8988 Fax +1 905 821-2565 Customer Service Tel 877 372 4371 Fax 800 329 8823 MEXICO USA Draeger Safety S.A. de C.V. Carretera San Luis Potosí Km 21 Bodegas No. 1 y 2 Condominio Industrial “Polígono Empresarial Santa Rosa Bloque SMED” Queretaro, Qro México, C.P.