Specifications

Table Of Contents
220
Reference Manual
00809-0100-4026, Rev HA
Appendix B: Product certifications
November 2014
Product Certifications
B.5 Hazardous locations certifications
Other temperature restrictions may apply beside the ones mentioned in the following sections.
For more information, see Reference Data on page 177.
B.5.1 North-American certifications
Factory Mutual (FM) approvals
The Rosemount 5400 Series Non-Contacting Radar Level Transmitter that has the following
labels attached has been certified to comply with the requirements of the approval agencies
noted.
Project ID: 3020497
Specific Conditions of Use:
1. WARNING – Potential Electrostatic Charging Hazard – The enclosure is constructed
from a non-metallic material. To prevent the risk of electrostatic sparking the plastic
surface should only be cleaned with a damp cloth.
2. WARNING – The apparatus enclosure contains aluminum and is considered to
constitute a potential risk of ignition by impact or friction. Care must be taken into
account during installation and use to prevent impact or friction.
E5 Explosion-proof for Class I, Div. 1, Groups B, C, and D;
Dust ignition proof for Class II/III, Div. 1, Groups E, F, and G; with intrinsically safe
connections to Class I, II, III, Div. 1, Groups B, C, D, E, F, and G.
Temp. Code T4
Ambient temperature limits: -50
°C to +70 °C
(1)
.
Seal not required.
Approval valid for HART, F
OUNDATION fieldbus, and Modbus options.
I5, IE Intrinsically Safe for Class I, II, III, Div. 1, Groups A, B, C, D, E, F, and G,
Class I, Zone 0, AEx ia IIC T4 when installed per control drawing: 9150079-905.
Non-incendive for Class I, II, Div.2, Groups A, B, C, D, E, F, and G suitable for Class II, III.
4-20 mA/HART model: U
i
= 30 Vdc, I
i
= 130 mA, P
i
= 1.0 W, C
i
= 7.26 nF, L
i
= 0 H
F
OUNDATION fieldbus model: U
i
= 30 Vdc, I
i
= 300 mA, P
i
= 1.3 W, C
i
= 0 nF, L
i
= 0 H
FISCO model: U
i
= 17.5 Vdc, I
i
= 380 mA, P
i
= 5.32 W, C
i
= L
i
= 0
Temp. Code T4
Ambient temperature limits: -50 °C to +70 °C
(1)
Approval valid for HART, FOUNDATION fieldbus, and FISCO options.
(1) +60 °C with FOUNDATION fieldbus or FISCO option.