Owner's manual

Cells Per Unit 6
Voltage Per Unit 12
Capacity 7.2Ah @ 20hr-rate to 1.75V per cell @25
(77 )
Weight Approx. 2.55 kg (5.62 lbs)
Maximum Discharge Current 100A/130A(5sec)
Internal Resistance Approx. 26 m
Operating Temperature Range
Nominal Operating Temperature Range 25
3 (77 5 )
Float Charging Voltage 13.5 to 13.8 VDC/unit Average at 25
(77 )
Recommended Maximum Charging 2.16A
Current Limit
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25
(77 )
Self Discharge CSB Batteries can be stored for more than 6 months at
25
(77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal F1/F2-Faston Tab187/250
Container Material ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15
~40 ( 5 ~104 )
Storage: -15
~40 ( 5 ~104 )
Constant Power Discharge Characteristics
Unit:W
(25
,77
)
Constant Current Discharge Characteristics
Unit:A
(25
,77
)
EVX 1272
12V 7.2Ah
Specification
Powered by
EVX 1272 is designed specially for electric vehicles,
such as electric golf cart, electric wheelchair, mower,
dust collector...etc. It has high cycling life, high
efficiency and long service life.
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V
7.01 4.19 3.08 2.49 1.79 1.44 1.20 0.820 0.680 0.395
1.67V
6.79 4.04 2.98 2.40 1.73 1.39 1.16 0.785 0.652 0.381
1.70V
6.57 3.91 2.89 2.34 1.68 1.36 1.13 0.770 0.640 0.375
1.75V
6.38 3.80 2.81 2.27 1.63 1.32 1.10 0.745 0.620 0.360
1.80V
6.20 3.70 2.73 2.19 1.58 1.28 1.07 0.720 0.600 0.345
1.85V
6.00 3.58 2.65 2.13 1.53 1.24 1.04 0.695 0.580 0.330
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V
84.1 50.3 37.0 29.6 21.5 17.3 14.4 9.81 8.20 4.53
1.67V
81.4 48.8 35.8 28.8 20.9 16.8 14.0 9.50 7.86 4.35
1.70V
79.2 47.3 34.8 27.9 20.2 16.3 13.6 9.24 7.72 4.27
1.75V
76.8 45.9 33.8 27.1 19.6 15.8 13.2 8.96 7.49 4.14
1.80V
74.4 44.4 32.7 26.2 19.0 15.3 12.8 8.67 7.25 4.00
1.85V
72.0 43.0 31.7 25.4 18.4 14.8 12.4 8.39 7.02 3.87
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H) Container height (h) Length (L)
100±1 (3.94±0.04) 94±1 (3.7±0.04) 151±2 (5.94±0.08) 65±1 (2.56±0.04)
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.