Data Sheet
Maintenance-Free Sealed Lead Acid Battery.
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99%.
【Design Life】
【
Float Charging Voltage
】
Up to 5 Years in Standby Service at 25
℃
13.5 ~ 13.8 VDC/Unit at 25℃ (77℉)
Eurobat (20℃) : 3-5 years, Standard Commercial 【Equalization Charging Voltage 】
【 Operating Temperature Range】 14.4 ~ 15.0 VDC/Unit at 25℃ (77℉)
【
Self Discharge
】
Less than 10% after 90 days, can be stored up to 6 months at 25℃ (77℉);
Fully recharging is required before usage, and charged sooner if stored
Storage: -15℃ ~ 40℃ (5℉~104℉) at higher temperature than 25℃ (77℉).
Design according with IEC 61056-1/2: 2012
Nominal Capacity
Terminal Breaking Torque 59 Kgf·cm / 51 Lbf·in / 5.73 N·m
Length (L) 197.0±2.0 mm 7.76±0.08 inch
Width (W) 165.0±2.0 mm 6.50±0.08 inch
Container Height (h) 170.4±2.0 mm 6.71±0.08 inch
Overall Height (H) 170.4±2.0 mm 6.71±0.08 inch
F.V/Time
5 MIN
10MIN
15MIN
30MIN
60MIN
90MIN
2HR
3HR
5HR
8HR
10HR
20HR
1.60V
176
113
85.0
51.8
30.6
22.2
17.7
12.6
8.01
5.25
4.28
2.31
1.67V
157
105
81.0
50.8
30.3
22.1
17.6
12.5
7.98
5.19
4.19
2.24
1.70V
149
101
78.7
50.1
30.2
21.9
17.5
12.4
7.96
5.17
4.16
2.20
1.75V
135
95.0
75.5
49.0
30.0
21.8
17.4
12.3
7.93
5.10
4.09
2.15
1.80V
121
88.3
71.7
47.6
29.8
21.7
17.3
12.2
7.88
5.03
4.03
2.10
1.85V
107
81.7
67.8
46.2
29.4
21.5
17.2
12.1
7.85
4.96
3.96
2.04
F.V/Time
5MIN
10MIN
15MIN
30MIN
60MIN
90MIN
2HR
3HR
5HR
8HR
10HR
20HR
1.60V
2110
1350
1020
622
367
266
212
151
96.1
63.0
51.3
27.7
1.67V
1886
1259
972
606
364
264
211
150
95.7
62.3
50.4
27.0
1.70V
1790
1214
945
600
363
263
210
149
95.5
62.0
50.0
26.5
1.75V
1620
1140
902
585
360
262
209
148
95.2
61.2
49.2
25.8
1.80V
1450
1060
860
571
357
260
208
147
94.8
60.4
48.3
25.1
1.85V
1280
980
814
555
353
258
207
146
94.2
59.6
47.5
24.5
Please refer to the official site for the latest rating confirmation. URL:
www.csb-battery.com
Issued:
180205
Tel: +31(0)180-418-140
Tel: +886-2-2880-5600
Fax: +31(0)180-418-327
Fax: +866-2-2888-3300
Tel: +86-10-5820-5336, 5820-5338
Fax: +86-10-5820-3053
GP series
GP 12400
12V 40AH
Valve Regulated Lead Acid Battery
Design for Standby Power Applications
Nominal Operating Temperature : 25℃(77℉)
Internal Resistance Approx. 8.5mΩ
Discharge : -15℃ ~ 50℃ (5℉~122℉)
Charge: -15℃ ~ 40℃ (5℉~104℉)
Specification
Nominal Voltage 12V (6 cells per unit)
40 Ah @20hr-rate to 1.75V per cell @25℃ (77℉)
Weight Approx. 12.63 Kg (27.84 lbs)
Maximum Discharge Current 400A (5sec)
Container Material ABS (UL 94-HB) & Flame Retardant (94-V0) available upon request
Dimensions
Short Circuit Current 1012A
Maximum Charge Current 12.0A
Terminal types B8 terminal to accept M5 bolt
Constant Current Discharge Characteristics Unit: A (25
℃
, 77
℉
)
Constant Power Discharge Characteristics Unit: W (25
℃
, 77
℉
)
Recognized under UL 1989,
and certified by ISO 9001, 14001.
Sales Offices
BEIJING OFFICE (CHINA)
Tel: +86-755-8831-6488, 8831-6775
Tel: +86-21-5046-1622, 5046-0833
BUSINESS HEADQUARTERS
Tel: +886-2-2880-5600
Fax: +866-2-2888-3300
USA OFFICE
EUROPE (EMEA) OFFICE
TAIPEI OFFICE
Fax: +86-755-8831-6075
Fax: +86-21-5046-1046
Tel: +1-817-244-7777 / 1-(800)3-CSB-USA (272872)
Fax: +1-817-244-4445
SHENZHEN OFFICE (CHINA)
SHANGHAI OFFICE (CHINA)