Data Sheet

Maintenance-Free Sealed Lead Acid Battery.
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99%.
Design for Standby Power Applications
Design Life Float Charging Voltage
Up to 5 Years in Standby Service at 25
13.5 ~ 13.8 VDC/Unit at 25 (77)
Eurobat (20) : 3-5 YEARS STANDARD COMMERCIAL Equalization Charging Voltage
Operating Temperature Range 14.4 ~ 15.0 VDC/Unit at 25 (77)
Self Discharge
Less than 10% after 90 days, can be stored up to 6 months at 25 (77);
Fully recharging is required before usage, and charged sooner if stored
Storage: -15 ~ 40 (5~104) at higher temperature than 25 (77).
Design according with IEC 61056-1/2:2012
Nominal Capacity
325A
3.0 A
--
ABS (UL 94-HB) & Flame Retardant (94-V0) available upon request
Length (L) 150.9±2.0 mm
5.94±0.08
inch
Width (W) 51.0±1.0 mm
2.01±0.04
inch
Container Height (h) 94.3±1.0 mm
3.71±0.04
inch
Overall Height (H) 98.6±1.0 mm
3.88±0.04
inch
F.V/Time 2MIN 4MIN 5MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 45MIN 60MIN 90MIN
1.60V 61.7 41.2 35.3 31.1 24.7 20.7 15.2 12.1 8.90 6.43 5.10 3.64
1.67V 55.0 38.8 33.7 30.1 24.0 20.4 15.1 12.1 8.84 6.38 5.06 3.62
1.70V 52.2 37.5 32.6 29.2 23.6 20.1 15.0 12.0 8.81 6.34 5.02 3.61
1.75V 47.1 34.6 30.8 27.2 22.5 19.2 14.6 11.8 8.68 6.26 4.97 3.58
1.80V 42.4 31.4 27.6 24.8 20.7 18.0 13.9 11.3 8.40 6.11 4.88 3.52
1.85V 36.8 27.0 24.1 21.7 18.5 16.4 12.7 10.5 7.95 5.79 4.63 3.38
F.V/Time 2MIN 4MIN 5MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 45MIN 60MIN 90MIN
1.60V 558 403 360 318 259 222 169 135 100 73.0 58.4 42.4
1.67V 529 388 347 308 254 218 167 134 99.1 72.4 58.0 42.3
1.70V 510 381 340 301 250 216 165 133 98.7 72.1 57.7 42.0
1.75V 472 364 319 287 238 210 159 132 98.2 71.7 57.3 41.7
1.80V 423 330 293 264 225 199 154 126 96.0 70.3 56.4 41.2
1.85V 374 287 261 238 204 183 142 119 91.7 67.7 54.6 40.2
Please refer to the official site for the latest rating confirmation. URL: www.csb-battery.com
Issued: 200927
Tel: +31(0)180-418-140 Tel: +886-2-2880-5600
Fax: +31(0)180-418-327
Fax: +866-2-2888-3300
Tel: +86-10-6597-8065/8165/8265
Fax: +86-10-6597-8565
360W @5min-rate to 9.60V per PCS @25 (77)
UPS series
UPS 123606
Valve Regulated Lead Acid Battery
General
Nominal Operating Temperature : 25(77)
Discharge : -15 ~ 50 (5~122)
Charge: -15 ~ 40 (5~104)
Specification
Nominal Voltage
12V (6 cells per unit)
Weight
Approx. 1.97 Kg (4.34 lbs)
Maximum Discharge Current
100/130 A (5sec)
Internal Resistance
Approx. 20.70 mΩ
Sales Offices
Short Circuit Current
Maximum Charge Current
Terminal types
F1/F2 terminal -Faston Tab 187/250
Terminal tightening torque
Container Material
Dimensions
Constant Current Discharge Characteristics Unit: A (25, 77)
Constant Power Discharge Characteristics Unit: W (25, 77)
BEIJING OFFICE (CHINA)
Tel: +86-755-8831-6488/6775/6075
Tel: +86-21-5046-1622/0833/0094
BUSINESS HEADQUARTERS
Tel: +886-2-2880-5600
Fax: +886-2-2888-3300
USA OFFICE
EUROPE (EMEA) OFFICE
TAIPEI OFFICE
Fax: +86-755-8831-6548
Fax: +86-21-5046-1046
Tel: +1-817-244-7777 / 1-(800)3-CSB-USA (272872)
Fax: +1-817-244-4445
SHENZHEN OFFICE (CHINA)
SHANGHAI OFFICE (CHINA)

Summary of content (1 pages)