 A 'referential' data error (assignments to 
certain items that don't exist either at the 
panel or in the software); 
Non-Critical Errors during a 'Normal' 
Communications Session 
(You'll be Asked to Correct These): 
 The same value being assigned to two 
different items 
(e.g., two users with the same card number); 
 Different settings for a single item (e.g., the 
software says user 8 has card number 1234, 
and the panel says user 8 has a different 
card number). 
Notes: These types of errors are typically caused by 
the same item being edited through the software and by 
a local admin. person at a system keypad. Beginning 
with Director v4.6, for conflicts pertaining to the same 
person or object, the data entered through the software 
will take precedence and be downloaded to the panel 
automatically. 
Getting Details on an Update Error 
To find out why a communications session 
may have failed, view the details for the 
specific session as described under "Viewing 
the Status of Previous Communications 
Sessions", previous. 
Software vs. Panel Conflicts (esp. large systems): 
Differences between the software database and 
settings entered locally through an LCD keypad can 
be identified by selecting "Check Database for 
Conflicts" from the Tools menu. For details, search 
for that topic in the index. 
As well, partial panel updates are indicated in the 
user list (grid view) with special colours:   
Yellow
: Partial updates pending (some panels have 
not been updated);   
Green
: Data for the user has been changed while 
partial updates were pending (the user's settings at 
the panels will be overwritten on next update). For 
details on the "user" screen, refer to the topic on 
Users. 
Correcting a 'Data Reception' Error 
A "reception", "not responding", or "failed to 
communicate" error can occur if the system 
panel (or modem) has been powered down, or 
if there is a problem with the serial cable, or 
the serial/COM port selection or settings. 
Troubleshooting Tip: If the status is listed as "Pending" 
for an extended period of time, this may mean: 
  The communications service was stopped on the PC 
associated with the panel or modem.  
  The serial port on the specific PC is not responding. 
In this case, try shutting down and restarting the PC. 
Then, recheck your connection. 
For a new system
: Ensure the panel connection is 
properly set up. For details, refer to "New 
Installation? Try the Wizard!", or "Panel Connection 
Overview". 
If you are Prompted to Fix a Data 
Conflict 
If a non-critical data conflict occurs during a 
'normal' communications session, you'll be 
asked to correct the error the first time you 
select that topic (such as "Users"). In general, 
you'll be asked to: 
 Choose between using a setting from 
Guardall Director, or a conflicting one at the 
panel, or; 
 Edit a value right-away to correct a conflict. 
Sometimes, you can choose to [Decide Later] on what 
data to use. In this case, the software data is retained, 
and the item (user, etc.) will appear with that setting 
highlighted in a different colour. Tip: To correct any 
conflicts that had been selected as "Decide Later", 
simply select the applicable area in the tree (such as 
User), and follow the 'Conflicting Data...' screens that 
appear. (Click Refresh or press F5 if required.) 
Correcting a 'Referential' Data Error 
If, for example, authority 'ABC' is deleted in the 
software, yet User 'Zig' is still assigned to that 
authority level at the panel, a 'normal' 
communications session will produce an error, 
and the update will not occur. 
To correct this you can either: 
 Find and correct the error, or; 
 Issue a "Send to Panel" to overwrite the 
panel's settings with those at the software. 