User`s guide
172  Guardall Director V4.74 User's Guide  21-0381E v4.7.4 
- Arm/Disarm and Tones
 (V4.4): Sets 
whether or not disarming will be supported 
through keypads and the general operation of 
the keypad sonalert/buzzer. 
Related: “Keypad Tone Reference”. 
Card Action 
- Ignore Pending Enrolment: This sets card-
enrolment readers to work on expired/disabled 
cards whether set for "pending enrolment" or 
not. If not selected, card-enrolment readers will 
affect only cards set as "pending enrolment". 
Application Tip: Cards can be set as 'Pending 
Enrolment' manually (e.g., when first issued), or when 
accepted at a reader set to do this. 'Expired' cards 
also includes cards that had been previously enabled 
for a set period of time by a reader set to do this. 
Related Settings
: 
  Users, Validation, Pending Enrolment. 
See: Users (Entrants/Panel Users).  
  Configuration, Doors, In Reader (or out...), 
[Card Action]. 
See
: Reader 1 & 2 Settings for a Door. 
 Bad Card/PIN  ( V4.20) 
These selections pertain to how the system will respond 
to repetitive invalid cards and/or invalid PINs at a reader 
or LCD keypad (i.e., an unauthorized person trying to 
gain entry). 
Related
:  Control & Status Panel Control & Status 
System [Clear User Lockout] 
Invalid User Detection 
- Maximum Bad PINs: The number of invalid 
PINs that can be entered before that person will 
be locked out. 
- System Lockout Duration: The duration that 
all users will be locked out in response to 
repetitive invalid access attempts from multiple 
users. This pertains to 'global lockouts'. 
- Maximum Lockouts Before Global Lockout: 
The number of individual users that can be 
locked out for an account before triggering a 
'Global Lockout' condition. This:  Will generate 
a local alarm message;  Can be transmitted to a 
monitoring facility (setting to follow);  Can be set 
to block access to all users on an area by area 
basis. 
Related: Configuration Areas Access "Bad 
Card Action" 
Tip
: A global lockout can be removed through: 
 Control & Status; 
 Visual Director, and/or:  A 'Command Point' custom 
input. 
- User Lockout Duration: The duration that 
users will be locked out in response to repetitive 
invalid access attempts. 
Tip: Long duration and/or permanent 'lockouts' can be 
removed through:  Control & Status;  Visual Director; 
 A 'Command Point' custom input. 
- Invalid Card Detection: Allows turning invalid 
card detection on or off, and setting the type of 
invalid cards to be counted. 
 Invalid Cards: Cards denied access due to: 
 Not in database;  Wrong site number; 
 Wrong version number; 
 High Risk
: Cards denied access due to:  Card 
expired;  Schedule expired;  Interlock violation; 
 Reader locked out;  Wrong area. 
- Maximum Invalid Cards: The number of times 
an invalid card can be presented before that 
card will be locked out (for the 'User Lockout 
Duration'); 
- Transmit Global Lockout Alarm: For a 
centrally-monitored facility, this determines if 
'global lockouts' are to be transmitted to the 
monitoring station. 
 Site Address and Mailing 
Address  
- Name: The name/description for the 
site/account (as set through the "Standard" tab). 
- Address: The address/location of the 
site/account. 
- [Copy Site Address to Mailing Address]: This 
sets the "Mailing Address" to match the present 
"Site Address". 
 Contact  
- Phone: The voice/contact phone number for the 
person who looks after the system. 
- Contact: The on-site contact person for the 
site/account. 
- Comments: Additional information pertaining to 
this site / account (optional). 
 Service PIN  
This pertains to the service user/login (000) with access 
to all features including configuration menus, service 










