User`s guide
21-0381E v4.7.4 
Welcome Report Control Admin 
Sys Config  Tech-Ref 
193
- Position: The position of the odd-parity 
'checksum' (1-40); 
- Start: The starting position of the data being 
checked for odd-parity (1-40); 
- Length: The number of digits being checked for 
odd-parity (1-40). 
Even Parity 
These settings pertain to even-parity checking, which 
helps to identify card 'misreads'. 
- Position: The position of the even-parity 
'checksum' (1-40); 
- Start: The starting position of the data being 
checked for even-parity (1-40); 
- Length: The number of digits being checked for 
even-parity (1-40). 
 Special  (Miscellaneous Items) 
- Door Fallback Mode: Cards to be granted 
access if the door controller module is unable 
to communicate with the main panel 
database:
: 
 
None: No cards/tokens accepted; 
  Valid Token Format: All readable 
cards/tokens accepted; 
 
Valid Site Code: All cards/tokens with the 
correct site code will be granted access; 
 
10 Fall-back Users: Only the users who are 
assigned as 'FallBack Users'. For details, 
refer to "Fall-Back Users...". 
- Unlock All Doors On Fire Alarm: If selected, 
all doors in all areas associated with this 
panel will automatically unlock when a fire 
alarm is detected by this panel. 
- AutoUpdate Card Version: For fixed-ID 
cards with a version number, this sets how re-
issued cards are to be handled. 
 = Grant access to a card with higher version 
number, and update the version number for the 
specific user automatically; 
 = Only cards that match the version number for 
each user will be granted access (must update 
manually when a card is re-issued). 
To set the initial/actual version number for specific 
card(s), refer to the section on "Users". 
For additional related settings, refer to "Card Version" 
(previous). Panel Version
: This feature requires  V3.2 
panel firmware. 
Equipment Settings (Pseudo 
/ Internal Inputs) 
Equipment Settings for a Panel 
The Equipment screen includes monitoring / 
signalling settings pertaining to various events 
associated with a specific panel (and/or 
expansion modules). These can also be 
thought of as 'pseudo' or 'internal' input points. 
How to Get Here 
Multi-Account Systems: First select [Account Folders] 
in the 'tree', and locate and double-click the desired 
account. 
MyTools Bar: System Equipment 
In the Tree
: Configuration (click the "+"), 
System, Equipment 
(Under the specific panel 
group and panel--if listed in the 'tree'.) 
Related Topic: "Other Desktop Choices" 
Tip: The Grid / Form toolbar-button allows selecting 
your preferred view-mode. 
Things You Can Do 
 View/Change an Equipment Selection 
(Monitored Condition ): Select one from 
the pop-up list at the bottom of the form. 
Tip: You can also use the 'browse' buttons to quickly 
scan through the defined items. 
 Blocking an Item from being monitored 
by the system: Select the specific item, 
and then set its 'preprocess' to 'disabled'. 
Grid View: Scan the list as desired. Tip: You can 
resize or maximize the window as desired, or use the 
bottom scroll-bar to view additional columns. 
For a list of the specific events, refer to the Equipment 
screen in the Guardall Director software. 