User`s guide
212  Guardall Director V4.74 User's Guide  21-0381E v4.7.4 
Pick-Lists (bottom of the form) 
-Panel Group & Panel references (optional): 
This is where you select a specific panel-
group and panel in a multi-panel system 
where the 'tree' is not
 set to show items on 
a panel-by-panel basis. For more 
information on this feature, refer to "Other 
Desktop Choices". 
- Door: This is where you select a door 
to view or edit. This area shows a 
reference number assigned by the 
system, and the name of the selected 
door, once defined; 
If the Name is Shown as "Elevator" (and the 
form is blank): These screens are 
placeholders for elevators (click [Filter] on 
the toolbar to hide elevator references). 
"Offset" values for each panel determine 
whether multi-panel sites will have 
consecutive versus repeating door numbers. For 
details, refer to the "Display Offsets" value under 
"System Panels and Displayed Item-Numbers". 
Top of The Form 
- Name: A suitable name/location for the door; 
 Standard  
- Module: The number (from the MODULE 
screen) for the door controller module 
associated with the specific reader/door. 
- Port Number: Whether this is the 1
st
 or 2
nd
door on the selected door-controller module; 
- Type of Readers: This identifies whether there 
are one or two readers associated with this door 
("In Only" vs. "In and Out"); 
Exception: For any door between two monitored 
areas, select "IN and Out" here, and set the area for 
the 2
nd
 reader (even if it is not present). 
(Provides an 'entry delay' in both directions when the 
area(s) are armed.) 
- Token Format: The card/token format 
associated with this door. Up to two 
card/token formats are supported for each 
panel, as defined through the System Access 
screen. 
"Wiegand" pertains to cards/tokens for readers with 
Wiegand data-format (Wiegand, Proximity, etc.). 
Similarly, "Magstripe" pertains to cards for readers 
with magstripe output (magstripe, bar-code, etc.). 
For details on setting up the card/token format, refer to 
"System Card-Access Settings". 
- LCD Name: A shorter version of the name to be 
displayed at LCD keypads. This is assigned 
automatically, and can also be changed if 
desired (max. 12 chars., plain text). 
- Controls Access to Area, and; Out Reader 
Controls Access to Area: This shows the 
area(s) associated with this door--as selected on 
the tab for each reader (to follow/below); 
 Extended  
Unlock Time 
- Standard: This is the duration that the door will 
unlock when access is granted for a typical 
entrant/user. 
- Challenged/Extended: This is the duration that 
the door will unlock when access is granted for a 
user who is set for "Extended 
Delay/Challenged". 
Auto Unlock 
- Schedule / "In Schedule" / "Out of 
Schedule": The schedule and conditions 
required for the door to unlock automatically 
based on a schedule. 
If a schedule is selected, the times 'Outside' of the 
schedule are treated in a similar manner to 'Inside' of 
the schedule. (For example
: You can have the door 
unlocked inside of the active schedule, and also 
unlocked after-hours, but only if/when the area is also 
disarmed.) 
Configuration Doors (First Tab Shown) 