To have the door simply re-lock at the closing time, set 
the "In Schedule" value as desired, and set the "Out of 
Schedule" value to "Locked". 
To have the door unlocking follow the area arming-
state only, set the schedule to "None", and "In 
Schedule" to either "Area is Off", or "Area is 
Stay/Off", as desired. 
If you do not
 want the door to unlock automatically 
based on a schedule and/or the area arming-state, set 
the "Schedule" to "None", and the 'In Schedule' value 
to "Locked".  
Circuit 
With converted TDC/PDC door controllers, this setting 
does not apply. 
- Reader Tamper Circuit: This is the type of 
circuit/wiring used with the reader tamper circuit 
for this door. 
Not Required: This disables the reader tamper input 
(i.e., the tamper input will not be monitored). 
Converted TDC/PDC Door Controllers
: These units 
do not support dedicated/separate reader tamper 
monitoring. 
- Door Circuit: This is the type of circuit/wiring 
used with the door contact for this door. 
------------------------- 
- Process Reader Tamper as Input Point:  
Future use. 
Other 
- Door Arming Level: The area arming levels 
for which the door is to be monitored. 
Tip: You may wish to use "Stay and On" with doors 
used to enter the facility, and "On Only" for all doors 
within
 the facility. 
- Bi-Colour LED Mode: Select this if the reader 
at this door has a single bi-colour LED (instead 
of the two separate LEDs). This setting must 
also be used if an 'arming station' is present. 
Note: Arming-station wiring differs from other readers 
(ensure the proper installation instructions have been 
followed). 
- Entry Detect: If selected (), persons will not 
be considered "In" the new area if they are 
granted entry, but do not open the door. 
Tip: This affects the in/out status of applicable users, 
and allows them to badge again to gain entry with 
antipassback turned on (see "Detect Antipassback", to 
follow / below). 
Related
: Configuration Areas 
Counting and Auto Arm. 
Note: This does NOT affect 'Activity' detection 
(Cfg.Areas Activity). 
Reader 1 & 2 Settings for a Door 
Defining a ‘Required Attendance’ Zone 
For time and attendance reporting, a ‘required 
attendance zone must be defined by setting 
the "Area" as "Outside" for all readers used to 
exit
 from this zone. 
See the "Area" description for more information. 
Note: For proper time and attendance tracking, there 
must be no other way to exit from the required-
attendance area (all exit doors must have a reader). 
 In Reader  
(and 'Out Reader'--if applicable)
Note: "In Reader" pertains to the 1
st
 (or only) reader for 
this door. "Out Reader" pertains to the 2
nd
 reader for 
this door (if applicable). 
The second reader, and In/Out processing is NOT 
supported on the older (2-reader) version of the door 
controller module. 
- Access to Area: This is the area associated 
with this reader (i.e., the area being entered
when using this reader). 
Time and attendance reporting requires that all 
readers used to exit from the "required attendance 
zone" be set as "Outside". 
This will typically pertain to the interior readers on the 
perimeter of the facility, and may also include 
additional readers (such as that allow entry to a 
cafeteria or fitness room). 
Card Mode 
- Schedule, and In / Out of schedule: These 
settings specify the basic method that 
entrants will have to use to gain entry at this 
door—i.e., via access token with or without 
keying-in a PIN at the reader. If scheduled, 
different entry requirements can be selected 
for when the schedule is active versus outside 
of the chosen schedule. 
UID vs. Card Number: The system can be set to 
require a full card number instead of the user-ID 
number. (Wherever you see "UID", a card number 
would have to be entered instead.) 