User`s guide
216  Guardall Director V4.74 User's Guide  21-0381E v4.7.4 
More Tabs 
 Request to Exit  
Standard 
- Request to Exit Required: Whether or not 
the RTE (REX) button on the door-controller 
module is being used. 
- Log Request to Exit: Whether or not an 
activity message is to be recorded each time 
the RTE button is pressed. 
- Request to Exit Circuit: This is the type of 
circuit/wiring used with the RTE (REX) circuit for 
this door. 
Advanced 
- Special Request to Exit Processing on 
Panel: This puts the main panel in control of 
the RTE processing (instead of the door 
controller). This is for 'interlocked' doors 
equipped with RTE buttons. 
- Do not unlock on Request to Exit (bypass 
door circuit only): This is for a monitored 
door that does not have to be unlocked to exit 
(avoids false "Forced Entry" alarms). 
Tip: This can also be used with a motion sensor 
instead of an RTE button. 
 Alarms  
Door Held/Forced Setup 
- Processing Required: Whether or not this 
door is to be monitored for forced entry and/or 
being held open too long. 
- Door Held Open Time: This is the length of 
time that the door can be held open (for a typical 
entrant/user) before it considered to be an alarm 
condition. 
- Challenged/Extended Held Open Time: This 
is the length of time that the door can be held 
open before it considered to be an alarm 
condition--after access was granted for a user 
who is set for "Extended Delay/Challenged". 
- Door Forced/Held Buzzer Time
 (V4.4): Future 
Use. This sets the buzzer duration for door held 
open and forced entry alarms. 
Held Open Alarm 
- Transmit / Sonalert / Siren: The area arming 
levels for which a 'Door Held Open' alarm will 
be transmitted, and/or cause a local sonalert 
or siren to be sounded. 
Forced Open Alarm 
- Transmit / Sonalert / Siren: The area arming 
levels for which a 'Door Forced Open' alarm will 
be transmitted, and/or cause a local sonalert or 
siren to be sounded. 
 Aux In/Out  
Auxiliary Input 
- Mode: This specifies how the auxiliary input on 
this door-controller module is to be used (none, 
monitor mag. lock, or as an Exit/RTE (REX) 
button used to trigger a door opener). 
Process Panel as Input Point: Future Use. Allows the 
auxiliary input for this door to be reserved (at the 
module), defined, and configured as a regular system 
input point. 
Converted PDC door controllers do not support an 
auxiliary input. 
- Auxiliary Input Circuit: This is the type of 
circuit/wiring used with the auxiliary input circuit 
for this door. 
MagLock Alarm 
- Transmit / Sonalert / Siren: The area arming 
levels for which a 'Mag Lock Bond Sense' 
alarm will be transmitted, and/or cause a local 
sonalert or siren to be sounded. 
Auxiliary Output Relay 
- Mode: Future Use. This specifies how the aux. 
output relay on the door-controller module is to 
be used (signal Door Held Open and Forced 
Entries, or to trigger an automatic door opener). 
Note: The "Door Opener" setting can alternatively be 
used with 'Card Disable' applications (e.g., turnstile 
card capture). 
Locator (previous/above)
: 
In Reader (or out reader),  
[Card Action], (Card Action=Disable Cards; 
Option=... : Auxiliary Output). 
Panel Control
: Future Use. Allows the auxiliary 
output relay for this door to be reserved (at the 
module), defined, and configured as a regular system 
output point. 
- Time: This is length of time that the auxiliary 
relay on the door-controller module will remain 
energized each time it is triggered. 










