User`s guide
21-0381E v4.7.4 
Welcome Report Control Admin 
Sys Config  Tech-Ref 
219
Pick-Lists (Bottom of the 
Form) 
-Panel Group & Panel references (optional): 
This is where you select a specific panel-
group and panel in a multi-panel system 
where the 'tree' is not
 set to show items on 
a panel-by-panel basis. For more 
information on this feature, refer to "Other 
Desktop Choices". 
- Elevator: This is where you select an 
elevator to view or edit. This area 
shows a reference number assigned 
by the system, and the name of the 
elevator, once defined; 
If the Name is Shown as "Door" (and the 
form is blank): These screens are placeholders for 
doors (click [Filter] on the toolbar to hide door 
references). 
"Offset" values for each panel determine whether 
multi-panel sites will have consecutive versus 
repeating elevator/door numbers. For details, refer to 
the "Display Offsets" value under "System Panels and 
Displayed Item-Numbers". 
Top of the Form 
- Name: A suitable name/location for the 
elevator (lift) cab; 
 Standard  
- Module: The number (from the MODULE 
screen) for the elevator controller module 
associated with the elevator cab. 
- Port Number: Whether this is the 1
st
 or 2
nd
elevator on the selected elevator-controller 
module; 
- Token Format: The card/token format 
associated with this elevator (lift) cab. Up to 
two card/token formats are supported for each 
panel, as defined through the System Access 
screen. 
"Wiegand" pertains to cards/tokens for readers with 
Wiegand data-format (Wiegand, Proximity, etc.). 
Similarly, "Magstripe" pertains to cards for readers 
with magnetic-stripe output (magstripe, bar-code, etc.). 
For details on setting up the card/token format, refer to 
"System Card-Access Settings". 
- LCD Name: A shorter version of the name to be 
displayed at LCD keypads. This is assigned 
automatically, and can also be changed if 
desired (max. 12 chars., plain text). 
 Extended  
- Bi-Colour LED Mode: Select this if the reader 
at this door has a single bi-colour LED (instead 
of the two separate LEDs). 
Note: Arming-stations are not supported in elevator 
cabs. 
- Insertion Type Reader: Ensures the access 
card is not read more than once when 
inserted and removed. 
- Floor Button Monitor: Whether or not other 
call buttons are to be disabled when a floor is 
selected
 (requires call-button-reporting wiring 
between the elevator unit and our floor relay board)
. 
- Floor Button Enabled Time: This is the 
duration that the allowed floor call-buttons will 
be available after a valid card is presented at the 
reader in the elevator (lift) cab. 
- Tamper Circuit: The type of circuit/wiring 
associated with the reader tamper 
input/sensor. ("Not Required" means this 
connection is not being used/monitored.) 
 Reader  
(Elevator (Lift) Reader Settings) 
- In Area: This is the area associated with this 
elevator cab. 
Time and attendance reporting requires that all 
readers used to exit from the "required attendance 
zone" be set as "Outside". 
This will typically pertain to the interior readers on the 
perimeter of the facility, and may also include 
additional readers (such as that allow entry to a 
cafeteria or fitness room). 
Configuration Elevators (1
st
 tab shown) 










