User`s guide
21-0381E v4.7.4 
Welcome Report Control Admin 
Sys Config  Tech-Ref 
223
- Building Name: A suitable description 
for the building or complex; 
- Floor: The first column contains a 
description for each floor. (Click within 
the name field, and type a suitable 
name); 
To change the name for a floor, select the 
present name, and enter the new name. 
The top cell in this column does not pertain 
to a floor. 
Sort Order
: To maintain proper order 
wherever floors are sorted by name, be 
sure to select names accordingly (e.g., "15 
Terrace", "14 Acme Offices", ..."01 
Parking2"). 
- Floor Desecure Schedule: This 
allows assigning individual schedules 
to floors (for finer control than the next 
field provides). (Select a schedule 
here if desired and/or refer to the next field.) 
Note: If more than one schedule is selected for a 
floor, free access to the floor will be provided during all 
times covered by any (one or more) of the schedules. 
- Desecure Schedule 1/2/3: These columns 
allow selecting up to three schedules during 
which free access will be provided to any floors 
selected. (Select a schedule at the top, and 
then click each floor to be associated with that 
schedule.) 
Access to all floors from a specific elevator (lift) cab 
can also be scheduled if desired. For details, refer to 
"Elevators (Lifts) and Associated Readers". 
Input Points—Monitored 
Sensors 
Input Points and Related Settings 
Input points are the system’s way of monitoring 
devices that detect smoke, motion, 
door/window openings etc. in each area. The 
Input Point screen allows fine-tuning basic 
monitoring characteristics, identifying the area 
the sensor is in, and whether or not it is on the 
perimeter of that area. 
Input Capacity Detail: 
ISM (square mainboard): 128 (120 external to the 
main panel). All of these can be wireless if keypads 
are set to zero each. 
xL (narrow mainboard)
: 256 (all can be external / 
wireless if the main panel and keypads are set to 0 
each). 
Also See: 
- Expansion Modules (I/O tab, then "Inputs:") 
- System Settings for each Panel (I/O Mapping tab) 
The point reset time is set globally for each account. 
Related
: Account Information, Setup, "Point 
Reset Time" 
 Account-Wide Panel Settings 
Emergency Keys
: The first 3 inputs on system keypads 
pertain to the built-in emergency keys rather than 
external sensors. 
Door Controllers and Suite-Security Keypads
: These 
devices have built in dedicated inputs that are set up 
directly under "Doors" or "Suite Security". 
Many pre-defined input point types are 
provided, in addition to custom input point 
types for fine tuning the monitoring character-
istics to meet your specific requirements. 
Custom point-types also allow setting up: 
 "Command Points"--allowing a button or sensor to 
command a device (e.g., area, door) on any/all 
panels; 
 Extended-delay sensors; 
 Vault/Safe input-points; 
  Guard-tour points (for guard-tour stations); 
  Area arm/disarm keyswitches, and; 
 Work-late buttons. 
YourAccount Floors 