Input Points—Pre-Defined Sensor Types 
Burglary Points: 
Type Arming Level Preprocess Class By-
pass
Chime Tx 
Off 
Tx 
Stay
Tx 
On 
Sonlrt 
Off 
Sonlrt 
Stay 
Sonlrt 
On 
Siren 
Off 
Siren 
Stay 
Siren 
On 
Entry Door  Perimtr  Door (area 1)  Burg  -- 
 
-- 
   
-- 
   
-- 
   
Entry Route  12hr  E/E Route  Burg 
 
-- -- 
 
-- 
 
-- -- 
 
Perimeter Perimeter Immed  Burg 
   
-- 
   
-- 
   
-- 
   
Interior Motion  12hr  Immed  Burg 
 
-- -- 
 
-- -- 
 
-- -- 
 
FAP - Motion  12hr  FAP  Burg 
 
-- -- 
 
-- -- 
 
-- -- 
 
Day Warning  24hr  Immed  Burg 
 
-- -- 
       
-- -- 
 
24hr Burglary  24hr  Immed  Burg 
 
-- 
                 
Life/Safety Points: 
Type Arming Level Preprocess Class By-
pass
Chime Tx Off Tx 
Stay
Tx On Sonlrt 
Off 
Sonlrt 
Stay 
Sonlrt 
On 
Siren 
Off 
Siren 
Stay 
Siren 
On 
Fire - A  24hr  Immediate  Fire-A 
                 
Fire 24hr 15s delay Fire   
                 
Fire 24hr Immediate Fire   
                 
Hold-up 24hr Immediate holdup
     
Aux Alert  24hr  Immediate  Emerg
                 
Supervisory Points: 
Type Arming Level Preprocess Class By-
pass
Chime Tx Off Tx 
Stay
Tx On Sonlrt 
Off 
Sonlrt 
Stay 
Sonlrt 
On 
Siren 
Off 
Siren 
Stay 
Siren 
On 
Supervisory 24hr  Immediate Spvsr 
 
           
Local Points: 
Type Arming Level Preprocess Class By-
pass
Chime Tx 
Off 
Tx 
Stay
Tx 
On 
Sonlrt 
Off 
Sonlrt 
Stay 
Sonlrt 
On 
Siren 
Off 
Siren 
Stay 
Siren 
On 
Local - 24hr  24hr  Immed  Burg 
 
           
Local-Stay&On Perimeter  Immed  Burg 
   
   
   
Local- 
Stay2 & ON 
Perimeters Immed  Burg 
   
 
 
Local - 
ON only 
12 hr  Immed  Burg 
   
 
 
Legend: 
 The 'Class' setting determines the type of 
alarm message to be transmitted; 
 Bypass means whether or not the input point 
will be bypassable; 
 Chime pertains to whether or not the 
triggering of the input will cause audible 
tones at keypads in the area (normally used 
with Entry points/routes to let you know that 
someone has entered); 
 Tx Off, Stay, and On pertain to the arming 
levels for which activation of the input point 
will cause an alarm to be transmitted to the 
monitoring station; 
 Sonlrt Off, Stay, and On pertain to the 
arming levels for which activation of the input 
point will cause keypad 'sonalerts' in the 
area to be sounded for one second. 
 Siren Off, Stay, and On pertain to the arming 
levels for which activation of the input point 
will cause siren outputs in the area to be 
sounded. 