On This Form (Standard  ) 
- Name: A suitable name indicating the operation 
or usage for this custom point type; 
- Preprocess: 
Either the duration that the 
point must REMAIN triggered before an 
alarm will be audited, or
 the point type / 
operation; 
Door: The 'Door' selection is normally used with doors 
that are monitored, but not electronically controlled for 
personnel access. For access-controlled doors, a 
dedicated 'Door Contact' input is provided on the door-
control module (which is set up through the Door 
screen). As well, door inputs cannot be set for a 24-hr 
monitoring, and cannot be bypassed (regardless of 
whether "bypassable" is selected or not). 
Extended
: This pertains to garage door sensors, and 
other applications where a longer delay time is 
desired. With this setting, the area "Extended" delay 
will apply, and the area can be armed while the input 
is 'tripped'. 
Keyswitch Arming/Disarming
: With 'pre-process' set to 
"Keyswitch...", the "Level" setting provides selections 
for "Arm" and "Disarm". The chime operation changes 
as well: If "Chime ()", and
 the area is set for "Stay on 
Fail to Exit", the area will be armed to 'Stay' if no users 
exit after turning the switch (not-Ok
 to Ok). 
Conversely, if the chime is not selected, the "Stay on 
Fail to exit" setting will be ignored (the area will fully 
arm to 'On'). Note: With an arming keyswitch, 
disarming is typically done through an LCD keypad. 
Guard Tour
: This pertains to guard-tour checkpoints 
(stations). For this application: 
+ The 'class' should be set as "supervisory"; 
+ The 'level' will typically be set as "24hr"; 
+ Any "Transmit" selections will be ignored (guard-tour 
point activity is referenced locally during the 
monitoring of a guard-tour). 
WorkLate
: This pertains to a button that can be 
pressed (during the pre-arm cycle) to delay the 
scheduled closing time for the area associated with 
the input-point. To set the time extension for 
WorkLate buttons in a specific area, refer to the "Work 
Late Input Point" setting under "Areas and Related 
Settings". 
Notice: 
Outside of the 15 minute pre-arm cycle, a 
worklate point acts as a standard burglary point. This 
allows (for example) a motion sensor to function as a 
worklate trigger during the pre-arm cycle, and as a 
standard motion sensor during its monitored times. 
Be careful to set the “Level” and “Transmit / Sonalert / 
Siren” values as suitable for your specific application. 
Command Point
: This allows a button or sensor to 
command a device associated with:  Any specific 
panel,  Any area or door number (ID) across all 
panels, or  All panels/areas/doors of an account. 
Tip: The actual command is selected when setting up 
the specific sensor(s)/input-point(s). 
Related Topic
: Configuration, Input Points, 
Command.  
See: Input Points—Monitored Sensors (previous). 
Activity Monitor
: This 'officially' detects activity in an 
area. For details, refer to "Activity Monitoring and 
Auto-Arming" in the 'Area' configuration topic. 
- Level: The arming levels of the area assigned to 
the point for which the point will be fully 
monitored by the system. 
Exception: For keyswitch operation, see the previous 
"Keyswitch" note. 
Activity Monitor
: The arming levels of the input 
point's area for which the point will be treated as an 
activity monitor versus a standard sensor (e.g., 
Burglary). 
- Class: The basic classification for the point / 
sensor (this is referenced in messages 
transmitted to the monitoring station); 
For Command Points: These are fixed as 
'Supervisory'. As well, other than issuing the specific 
action, command-points are monitored only for 
'Tamper' conditions. 
------------------------- 
- Bypassable: Whether or not the point can be 
bypassed (by a user with 'bypass' authority) 
should the need arise (e.g., to allow arming an 
area with a broken window, faulty sensor, etc.). 
- Chime: Whether or not three short beeps will be 
signalled at keypads in the area assigned to this 
point whenever the point is triggered (this can 
be ‘toggled’ off at a keypad by pressing ƒ5); 
Exception: For keyswitch operation, see the previous 
"Keyswitch" note. 
- Pre-Alarm Warning: For associated input-
points, alarm transmission (to the central 
station) will be delayed as per the "Pre-Alarm 
Delay" setting (for the specific 'area'). During 
the delay, keypad sonalert(s) will be sounded, 
giving an authorized user time to "Silence" the 
alarm at a keypad. (Selecting "Verify User" will 
cancel the alarm transmission.) 
Siren Time: To allow a pre-alarm warning to occur, 
the siren time for the panel must be greater than 30 
seconds. (Siren Time appears under: 
Configuration, System, Standard ) 
For details on setting the "Pre-alarm Delay" time, refer 
to "Areas and Related Settings". 
To assign an area to be monitored by a specific 
keypad, refer to "Expansion Modules". 