User`s guide
21-0381E v4.7.4 
Welcome Report Control Admin 
Sys Config  Tech-Ref 
233
reference number assigned by the 
system, and the name of the output, 
once defined; 
Output-point numbers are assigned by the 
system when a expansion module that 
supports 'outputs' is set up. The number 
assigned to each 'output' is based on the 
module installation order, and the number 
of 'outputs' supported by (reserved for) 
each module. 
Tip: The "Module" and "Range" areas 
(blue text) show the device associated with 
the output-point, and the range of outputs 
for that device. 
"Offset" values for each panel determine 
whether multi-panel sites will have consecutive versus 
repeating output-point numbers. For details, refer to 
the "Display Offsets" value under "System Panels and 
Displayed Item-Numbers". 
On This Form 
- Name: A suitable name for the device (output 
point) indicating its location and/or usage, etc.; 
- Output (and the small [...] button): Click the 
small button to access a second screen for 
setting up the output. For an existing output, the 
selected function(s) are shown next to the [...] 
button; 
(See the next screen/section for details.) 
- Output Version: This shows the panel firmware 
revision need to support the presently-defined 
output equation. 
Note: In general, the following items require panel 
firmware v4.2 or newer:  Multi-segment output 
equations;  Timed or inverted output actions;  Type 
E (European) selections;  Cadence functions. 
- Compatibility Response: This shows whether 
or not the output equation is compatible with the 
panel firmware (i.e., after one communications 
session with the panel). 
- Module: This is "Panel" (a system panel) or the 
module associated with the specific output-point 
number. 
- Range: This is the total range of output-point 
numbers associated with the specific module (as 
defined by the software when each module is 
set up). 
Tip: The number in brackets, such as "(1)", pertains 
to the location of the physical output connection on the 
specific module. 
Configuring an Output Point 
 Open the Output Point configuration form, 
and add or select the desired output. 
 Click the small [...] button to access this 
screen. 
 Click an "item" (such as "unassigned") to 
select a new value. (Additional items will 
appear as you go along--where applicable). 
Tip: See the "Item" descriptions, to follow. 
 Use the Up/Down arrows to scroll in pop-up 
lists. 
 Right click items to select a command (e.g., 
Invert, Insert, Remove). 
----------------------------------------------- 
Note
: Selections under [ More >> ] are for 
reference/internal use only. 
Items": Event Type, Target Item,  
Event
, "
", Output Action, 
Mapped Input
Note: This pertains to an output being triggered by a 
single condition. For complex equations and 'Boolean' 
operators, see "Multi-Condition Equations", to follow / 
below. 
 Event Type
: The general type of event that will 
trigger the output (System, Schedule, Holiday, 
Area, Point (sensor), Output, Door, Elevator (lift), 
Floor, Module, or Suite-security keypad); All 
function-key selections now appear under "Area". 
Note: Selections appear only for device-types that 
exist in your system. "System" pertains to events 
associated with the specific main/system panel. 
Exception
: Cadence selections (at the bottom/end of 
Configuration Output Points [ ... ] (Edit Output) 