268  Guardall Director V4.74 User's Guide  21-0381E v4.7.4 
(Although--with software and firmware 
versions indicated above--a single HSC-IP 
module can be used for both features at 
the same time. 
  Networking Ports: The Director software 
requires exclusive access to port 443, and 
this port must NOT be blocked on the 
network. 
Set-up Overview: 
  Hardware: The IP module (and receiver) 
must be set up--as applicable. Refer to 
the documentation for the specific version 
of IP module or receiver. 
e.g., HSC-IP Module v4: 21-3691x 
e.g., R1000 Receiver: 21-3690x
  Certificate Files: Obtain through your 
dealer. 
Assign for the Director Server:  
[Management], PC Access (+), Server Access. 
Details
: Server Validation Certificates 
Assign for each Communication Client:  
[Management], PC Access (+), Client Access. 
Details
: Client Access (Allowable Client List) 
Assign for a Receiver (Monitoring via HSC-IP):  
Refer to the programming guide for the receiver. 
e.g., R1000 Receiver: 21-3690x 
  Director Software: 
Client/Server via Secure IP: No set-up needed. 
Exception
: If connecting out through a proxy-server, 
some proxy information must be entered in the login 
screen. Get an 'IT' person to help you with this. 
PanelPC via Secure IP:  
1) "Encrypted IP" must be selected for the 
Communications Device, Communication Pool, and 
Panel Group. 
More
: Panel Connection Overview 
2) Configuration, ->System, ->Communication. 
All settings as usual, plus: 
Interface IP Address: This is the IP Address or 
name (FQDN) for the panel's IP interface--which 
must also be as supported by the certificate. 
Contact your IT rep. if you need assistance.  
Interface IP Port: 443 (typical). 
Monitoring via HSC-IP:  
Configuration, ->System, ->Communication, 
->SIP / HSC: SIP Mode: SIP over IP.  
Note
: Firmware rev. levels, plus IP module set-up will 
determine the use of HSC-IP protocol. 
Basic IP Connections / Older 
Firmware 
Note: The Director software is backward-compatible 
with existing IP connections. These are not 
recommended for use on a public domain. 
Beginning with version 3.30, the Guardall 
Director software allows connecting to a panel 
through an IP connection (LAN/WAN), and/or 
reporting to a central monitoring facility through 
an IP connection (SIP reporting). 
The PC-to-panel connection via IP does not 
require any specific revision of panel firmware. 
The SIP reporting feature requires v3.30 panel 
firmware or higher. 
IP connections include an IP interface board 
that must be properly set up for use with the 
Guardall Director system. 
All details on setting up an IP connection 
are documented separately. For full 
details, refer to the instruction manual 
included with your IP interface board. 
Tip: This may also be available on the Director 
CD as a printable/viewable 'PDF' file. 
Panel & Software Revisions: Guardall Director 
software  V3.2 and higher can connect with panels 
V2.0 and higher. 
Associated panels must be the same rev. level, and 
the Director software must typically be upgraded to 
the same level or higher. 
Exception
: V3.3 panels OK with V3.20 software (if IP-
related features are not needed). 
PC-to-Panel—Direct 
Connection 
Panel & Software Revisions: Guardall Director 
software V3.2 and higher can connect with panels 
V2.0 and higher. 
Associated panels must be the same rev. level, and 
the Director software must typically be upgraded to the 