User`s guide
21-0381E v4.7.4 
Welcome Report Control Admin Sys Config 
Tech-Ref 
279
Transfer Settings and Test for Basic Operation 
Step (Do This):  For details, refer to: 
14) Set up and activate a "Send to Panel" 
communications session with the specific 
panel(s). 
"Panel Communications and Updates" 
15) After the data is transferred, test that the 
sample card can unlock the applicable door(s). 
For details on using a system LCD 
keypad for various tasks, refer to the 
xL (panel/keypad) User's Guide. 
Finish Data Entry for All Devices, Areas, 
and Desired Operation 
With basic data entry and testing completed, 
now you can define the rest of the devices in 
the system, and customize settings for desired 
operation. Your database of 'Users' will need 
to be entered as well. 
For a large system, you may wish to divide the 
user-list and system devices into manageable 
'chunks'—so you can keep track of what's 
been done, and what still needs to be done as 
you go along. 
Tip: You may wish to set up any required "Schedules" 
right-away, since they can be assigned to user-
authorities, areas, and readers. 
For more information, refer to the 
"Administration" and "Configuration" chapters 
in the table of contents (at the front of this 
guide). 
Importing Settings from an 
Existing Guardall Director 
System Panel 
Panel & Software Revisions: Beginning with 
V3.20, the Guardall Director software can connect 
with panels V2.0 and higher. 
Associated panels must be the same rev. level, and 
the Director software must typically be the same level 
or higher. Exception
: V3.3 panels OK with V3.20 
software (if IP-related features are not needed). 
For an existing Guardall Director system that 
had been programmed locally (without 
software), the settings from a single panel can 
typically be imported into the software. Typical 
steps appear below. 
Note: These steps pertain to sites that were 
programmed through a system keypad
. For a site 
being upgraded from an earlier version of Guardall 
Director software, refer to "Upgrading from an Earlier 
Version of Software". 
1)  Before You Begin: Obtain this information 
from a service person for the site. 
+ The panel serial number (S005:0, or check 
for a small hand-written label). 
+ The "Panel Code" / Account UID (S001:5) 
and "Third-Party Password" (S005:1). 
Be sure to write down the information above, as it 
will be needed in step 6. Note: If the panel's 
"Third-Party Password" is zero (0), it must
 be set 
to a non-zero value through a system keypad. 
Conversely, if the "Panel Code" (Account UID)" is 
zero, it will be set automatically by the software. 
2)  Set the "Account Name" as desired. For 
details, refer to "Working with Accounts and 
Folders". Multi-Account Systems: Rename the 
default 'Account folder' and Account name if 
desired (or set up a new account folder and/or 
'Account' to be associated with the specific panel). 
3)  Rename the default Panel Group and Panel 
name if desired (or set up new ones if 
desired). For details, refer to "Panels, Panel 
Groups, and Related Settings". 
4)  Set up all items as required for connecting 
with the panel. For details, refer to "Panel 
Connection Overview". 
5)  Set up and activate a "Get from Panel" 
communications session. For details, refer 
to "Panel Communications and Updates". 
6)  This would be a good time to check what 
information was obtained from the panel. 
The list of users is a good place to start. For 
details, refer to "Users (Entrants/Panel 
Users)". 