User`s guide
282  Guardall Director V4.74 User's Guide  21-0381E v4.7.4 
(Any three-letter acronyms typically pertain to different 
types of door-controller modules, and other 
peripherals.) 
To make use of your available capacities, the 
panel "Feature Set" needs to be set 
appropriately. 
For details, refer to "Account-Wide Panel Settings". 
Note: Some of the capacities that follow also require 
additional panel memory to be installed (see the next 
table). System upgrades may involve a combination of 
upgrading software, hardware, and/or licensing (refer to 
the instructions provide with the upgrade kit). 
Software Versions and Basic Capacities 
License =>  PRIME  Enterprise  Enterprise Elite 
Users 1,000 10,000 64000 
Doors * 
(+ Elevators/Lifts) 
16 * 1920 *
/ 3200 ‡ / 8000‡ 
1920 *
/ 3200 ‡ / 8000 ‡ 
Graphical User Interface 
(floating licenses) 
2 (V4.73) § 
10 +1/+5 ‡ 50  10 +1/+5 ‡ 50 
Communication Clients  1 
3 / 10 ‡ / 25 ‡  3 / 10 ‡ / 25 ‡ 
Panels 1 
60 / 100 ‡ 250 ‡  60 / 100 ‡ 250 ‡ 
Accounts 1 
10 / 3000 ††  100 / 3000 †† 
Visual Director (and 
unlimited NetVision DVRs) 
 (V4.73) 
   
Photo-badging 
 (V4.73) ‡ 
 ‡   ‡ 
Client/Server 
Deployment 
 (V4.73) § 
   
Database Views and 
SQL Server Support 
     
ERM Capability 
   
 ‡ "Adv. Features" 
Remote Software 
Download (V4.7) 
 (V4.73) § 
   
VeDVR / NVe DVRs 
-- +1 / +5 DVRs 
1 only (V4.73) §
(V4.71) 
1 - 1023 ‡ 
(V4.71) 
1 - 1023 ‡ 
March Networks DVRs 
-- +1 / +5 R5 DVRs 
-- R4 DVRs (unlimited) 
 
 
(V4.7) 
1 - 1023 ‡ 
 ‡ 
(V4.7) 
1 - 1023 ‡ 
 ‡ 
Notes and Exceptions
: ‡ Optional via licensing; § For new systems / updated hasp key only; 
* To support doors/access-control and/or 'memory model' 4, xL panels (narrow mainboard) require a feature 
expansion board;  Client/Server operation also allows multi-server login;  Adding panels allows for more areas, 
sensors, doors, etc.;  Elevator (lift) capacity is shared with the door capacity;  Floor capacity is the same per panel 
or account (124), and can be for one building, or shared across multiple buildings;  Suite capacity is per panel, and 
is reduced by 5 for each (other type of) hardware module present. †† Optional via HASP key. For a full SQL server 
installation (not express) as set up and managed separately, and as selected during installation or through the DB 
generator utility; 
Note
: Playback for video events is NOT supported for March R4 DVRs. 
Converted TDC/PDC Door Controllers
: Up to 10 per panel (combined total). The above lists show only the items that 
are different between the two system versions. The sections that follow describe the overall maximum system 
capacities. * Support for suite-security keypads requires a "Feature-Set" selection of 5 or higher. To set this value, 
refer to "Account-Wide Panel Settings". 