User`s guide
21-0381E v4.7.4 
Welcome Report Control Admin Sys Config 
Tech-Ref 
283
System-Wide Capacities 
Client / Server Operation: This is dependant 
upon your software licensing (as managed 
through the license-manager software). 
No. of Client Workstations and/or Panel-
Connection Ports: These items are limited 
only by the licensing agreement, but subject to 
network performance, and system size / 
activity. 
Operators: Not limited (subject only to hard-
drive space). 
Message Log Capacity (V4.7x): The 
following number of messages are supported: 
Message 
Type 
Typical 
(SQL 
Server 
Express) 
SQL 
Server 
Inst. 
Option 
After 
Auto-
Purge 
Alarm/event 
messages 
1,000,000 20,000,0
00 
Minus 
5% 
Communi-
cations logs 
50,000 50,000 Minus 
10% 
Operator 
logs 
240,000 240,000 Minus 
10% 
Related Topics: Removing old Activity or Audit Logs 
(Purge) 
Saved Reports: Not limited (subject only to 
hard-drive space). 
Account Capacities 
Panels and Connections: Number of panels 
per account is limited by the software 
licensing, and is also subject to PC and 
network performance. Up to 30 panels at a 
time can be connected together to share a 
single connection to a PC or modem. The 
number of panel connection ports is limited by 
licensing, port/modem availability, and PC 
performance. 
Notes / Exceptions: 
  The "Prime" version of the Guardall Director software 
('feature set' 1, 2, 3, and 4) is limited to 1 panel per 
account. 
  Automatic dial-in to transmit messages to the 
Guardall Director system is not supported through a 
shared connection (a modem is needed for each 
remote panel). 
  Remote management through the panel's built-in Bell 
103 (300 baud) modem/dialler is limited to 'feature 
set' 1 – 3 (one panel / up to 300 users per account). 
Users: Same as the 'per panel' capacity (see 
the next table). 
Card No./IDs vs. Firmware: Beginning with V3.2 panel 
firmware, 32-bit ("9.5 digit") card numbers are 
supported (previously 7 digits). This also requires 
V1.5 door/elevator controller firmware. With panel 
firmware V3.2, card IDs can be up to 999999999.  With 
firmware V3.31, card numbers can be up to 
4294967295. 
Authorities: Same as the 'per panel' capacity 
(see the next table). 
Schedules: (Depends on panel type and 
memory-model supported.) 
50: V4.3, or panels set to memory-model 1-3; 
100 (V4.4): Panels set to memory-model 4-7; 
250 (V4.4): Panels set to memory-model 8 or higher. 
Holidays: 32 V4.3; 50 V4.4 
Note: "Holiday" 1 and 2 are reserved for the dates to 
change between daylight savings and standard time. 
Floors: 124 (in a single building, or the 
combined total for multiple buildings). 
Guard Tours: Not limited (subject only to 
hard-drive space). 
For each Main Panel (per panel-type 
+expansion, licensing and 'Feature-Set') 
Panel Legend (for this table only, col. 2): P0: ISM 
(square mainboard); 
P1: xL (narrow mainboard); fe: +F
eature Expansion 
board. 
Feature 
Set 
Panel + 
Expansion 
(½, 1, 2 MB) 
Doors (+ 
Elev
./Lifts) 
Auth. 
Levels
History 
Events 
(Logs) 
Users User 
Names at 
Keypads
User LogOn  Panels  Minimum 
Software 
Needed 
1 *  P0 / P1 / P1fe  16 / 0 / 16  30  1024  20  Yes  Pin Only  1  Prime (opt.) 
2 *  P0 / P1 / P1fe  16 / 0 / 16  30  1024  100  Yes  2d ID + Pin  1  Prime (opt.) 
3 *  P0 / P1 / P1fe  16 / 0 / 16  30  1024  300  Yes  3d ID + Pin  1  Prime (opt.) 
4 *  P0 / P1fe    16  100  2048  1000  Yes  3d ID + Pin  1  Prime (opt.) 