User`s guide
284  Guardall Director V4.74 User's Guide  21-0381E v4.7.4 
5 †  P0 / P1fe   32  100  2048  1000  Yes  3d ID + Pin  60 / 100 / 
250 
Enterprise 
6 †  P0 / P1fe   32  100  2048  2000  Yes  4d ID + Pin  60 / 100 / 
250 
Enterprise 
7 †  P0 / P1fe   32  100  1024  4000  No  4d ID + Pin  60 / 100 / 
250 
Enterprise 
8 †  P0 / P1fe, +½   32  500  8192  10000  Yes  4d ID + Pin  60 / 100 / 
250 
Enterprise 
9 †  P0 / P1fe, +½   32  500  8192  10000  No  4d ID + Pin  60 / 100 / 
250 
Enterprise 
10 †  P0 / P1fe, +1   32  500  8192  20000  Yes  5d ID + Pin  60 / 100 / 
250 
Ent. Elite 
11 †  P0 / P1fe, +1   32  1000  16384  20000  No  5d ID + Pin  60 / 100 / 
250 
Ent. Elite 
12 †  P0 / P1fe, +1   32  1000  16384  20000  Yes  5d ID + Pin  60 / 100 / 
250 
Ent. Elite 
13 †  P0 / P1fe, +2   32  1000  65536  64000  No  5d ID + Pin  60 / 100 / 
250 
Ent. Elite 
14 †  P0 / P1fe, +2   32  1000  32768  64000  Yes  5d ID + Pin  60 / 100 / 
250 
Ent. Elite 
†  Supported 'feature-set' depends on your software 
licensing (as managed through the license-manager 
software). Feature-sets higher than 4 are supported 
only with the "Enterprise" version of Guardall Director. 
*  Local user admin. (via keypad) is supported in all 
systems, while local system configuration is supported 
only in single panel systems set to "Feature Set" 1, 2, 
3, or 4. Exception: Keypad programming is 
supported in all systems for any 'application' modules 
that require this due to custom settings stored only at 
the module itself (HSC/printer module, RF/wireless 
module, and Smart PODs). 
For details on setting the 'memory model', refer to 
"Account-Wide Panel Settings...". 
Common Per-Panel Capacities 
(not based on 'Feature-Set') 
Expansion / Application Modules: 24 
system LCD keypads and/or other modules, or 
60 suite-security keypads (see exceptions). 
Exceptions: Suite-security keypads can be mixed with 
other modules if desired (the capacity for suite-security 
keypads is reduced by 5
 for each system LCD keypad, 
and each other expansion / application module added. 
(For example, with 2 system keypads, 3 door 
controllers, and one point expansion module, a full-
capacity "Enterprise" system could still support 30 suite-
security keypads). 
Converted TDC/PDC Door Controllers
: Up to 10 per 
panel (combined total). 
Areas: 16 monitored 'areas' per panel; 
Doors:
 The "Enterprise" version of the 
software supports up to 32 doors per panel. 
The "Prime" version supports a single panel 
with 16 doors. 
Note: To support doors/access-control, xL panels 
(narrow mainboard), require a 'Feature Expansion 
Board'. 
Elevators: The "Enterprise" version of the 
software supports up to 32 elevator (lift) cabs.
Exception
: This is shared with the door capacity (max. 
32 combined total).
Floors:
 The "Enterprise" version of the 
software supports 124 unique access-
controlled floors. 
(These can be in a single building, 
or the combined total across multiple buildings.)
Monitored Sensors (Input Points): 
(Depends on panel type, and number of point 
expander modules.) 
Up to 128: ISM panels (square mainboard). 
Up to 256 (V4.4): xL panels (narrow rectangular 
mainboard). 
Input Capacity Detail: 
ISM (square mainboard): 128 (120 external to the 
main panel). All of these can be wireless if keypads 
are set to zero each. 
xL (narrow mainboard)
: 256 (all can be external / 
wireless if the main panel and keypads are set to 0 
each). 
Also See: 
- Expansion Modules (I/O tab, then "Inputs:") 
- System Settings for each Panel (I/O Mapping tab) 
Programmable Outputs: 128 per panel. 