User`s guide
21-0381E v4.7.4 
Welcome Report Control Admin Sys Config 
Tech-Ref 
295
System / Hardware 
Reference 
System Design Aspects 
(Topology) 
The following concepts can be 'mixed and 
matched' as desired when designing a system: 
PCs / Environments: The Guardall Director 
software can be installed for use on a single-
PC, or across multiple PCs in a network 
environment. Different aspects of the software 
will be installed, depending on what each PC is 
used for (database server, operator 
workstation, and/or for panel/modem 
connections). 
Client access to the server database is protected—
based on a definable list of clients, each with its 
associated network "IP address". Multiple central 
databases can also be managed if desired. An 
operator can logoff from one server, and then login to 
another one. 
Sites / Accounts: For managing larger 
systems, and systems in multiple locations, the 
Guardall Director software uses the concept of 
"Accounts". Each account can be a single 
panel, or many panels in different locations.  
Essentially, an account is a set of panel(s) or 
site(s) that will be managed as a single entity 
(shared users, etc.). Accounts can be 
arranged in folders, which are referenced 
when assigning operator permissions. 
Selecting an account shows the monitoring window with 
messages received from the specific account, and 
provides access to admin. and configuration topics for 
the selected account. 
Panels and Connections: Each account can 
include 1-60 panels (subject to licensing and 
PC / network performance). Up to 30 panels 
at a time can be connected together to share a 
single connection to a PC or modem. 
Panels can connect through any PC in the 
Guardall Director system. A specific 
connection can be direct (via cable), or using 
dial up modems, or through a network (via IP). 
Cable connections are 'serial', with or without 
conversion to "RS485". (RS485 connections 
allow for longer distances, and/or multiple 
panels per connection.) 