User`s guide
21-0381E v4.7.4 
Welcome Report 
Control  Admin Sys Config Tech-Ref 
87
- Door (bottom of form): This is where 
you select a door to view its status or 
issue commands. This shows a 
reference number assigned by the 
system, plus the name/description of 
the door as defined under 
'Configuration'. 
If some Door numbers are missing: 
Elevator and door numbering is shared (1 - 
32), but the elevators will not be listed here. 
- Door Command: Shows the status of 
the selected door, and provides 
selections for unlocking/relocking it (if 
you have the authority). 
If cards are presently 'locked-out', you'll 
need to reinstate card-access before 
unlocking the door. (Set the "Reader State" 
as "Normal".) 
Tip:  "Momentary" pertains to the defined "Unlock 
Duration" (such as when a person uses their access 
card), and "Pending" means the command will be held 
until after one valid user gains entry at the door. 
- Door Status, Door Alarm, and "Wandering 
Patient": The present status of the door, and 
whether or not this is considered to be an 'alarm' 
(i.e., 'not OK'), plus whether or not the 
"wandering Patient" feature is in effect for this 
door. 
- Tamper: Whether or not tampering has been 
detected for the RTE (REX) circuit, the main 
reader, or the auxiliary reader. 
- Reader 1 / Reader 2 In Area X: Status/control 
topics for the selected reader and its associated 
area, plus selections for controlling each reader 
(if you have the authority). Selections include 
lockout or reinstate card access, and/or change 
various operating characteristics. 
Reader Mode, 'Toggle Lock' and 'Toggle Lock 
Authorized': Cards granted access at the reader will 
cause the door to toggle between lockedunlocked. 
'Authorized' means this will work only for users with 
'Door Command' authority. 
Note: Locking-out cards automatically causes the 
door to lock. 
For details on the various modes and commands: 
  In the section on using maps and cameras, see: 
"Controlling an Area or Device" (look for "Door 
Commands"); 
  In the configuration chapter, see: "Doors, Readers, 
and Related Settings". 
- Grant Last User: If the last user at this reader 
was denied access, this selection will issue a 
'Momentary Unlocking', and log that card/user 
as being granted entry. 
  Cards can be denied due to being expired, locked 
out, wrong time, wrong door class, etc. -- as long as 
they are defined in the system. 
  This feature will be unavailable if someone else is 
granted entry, or after 5 minutes from the time the 
person was denied access (although they can 
simply present their card/token again). 
  This may be used in conjunction with an event-
triggered camera-view for the door (so a remote 
attendant can see the person). Related Topics: 
"Initial Set Up of: Views, Maps, Cameras" (step 3b).  
  This can also be used in conjunction with the pop-
up "Photo-Verification" feature (if it is set to trigger 
on 'Access Denied' events).  
Related Topics: "Visually Verifying Users (Photo-
Verification)" 
 This cannot
 be used (or does not apply) with: 
- Cards being enrolled or disabled at a reader set 
 to do this (although it will apply for cards denied 
 due to wrong area/time, etc.); 
- Access being denied due to door interlock 
 violations or area/disarm authority issues. 
Checking Status or 
Controlling Elevators 
Elevator (Lift) Status and Control 
The elevator status screen shows the status of 
elevators in the system, and allows changing 
the operating characteristics for elevator 
readers. Selections are also provided to apply 
Control & Status Panel Control & Status Doors 