 To change the reader access 
requirements or operating 
characteristics, refer to the "Reader 1 
in Area X" selections. 
 To apply or remove access-control 
(secure or desecure) for an individual 
floor--as accessed from a specific 
cab, refer to the "Elevator Floor 
Status" selections. 
In 'Grid' view, use the small button to the 
right of your desired topic to select a 
command. 
If commands or button(s) are not available, 
this means you do not have the authority to 
control elevators. 
Elevators and/or specific floors can be set to 
desecure and resecure in-sync with a 
desired schedule. For details, refer to the 
configuration
 topic for elevators and/or 
floors. 
- Elevator (bottom of form): This is where you 
select an elevator to view its status or issue 
commands. This shows a reference number 
assigned by the system, plus the 
name/description of the elevator as defined 
under 'Configuration'. 
If some Elevator numbers are missing: Elevator and 
door numbering is shared (1 - 32), but the doors will 
not be listed here. 
- Elevator Command: Shows the status of the 
selected elevator, and provides selections to 
secure or de-secure all floors as accessed from 
this elevator cab only
 (via appropriate authority). 
- Elevator Status, and Elevator Bypass: These 
areas show the basic status of the selected 
elevator (lift) cab, and whether or not the manual 
override (bypass) input has been tripped. 
Manual Override (bypass) Input: Triggering the 
manual override (bypass) input on the elevator 
controller (typically connected through a key-switch) 
will desecure all floors as accessed from this cab (this 
is the same as selecting "desecure" for the elevator 
command). 
- Alarms: This area shows the status of various 
alarm conditions (inputs) for the specific elevator 
controller, plus whether or not the relay boards 
are communicating (on-line). 
Fire Bypass: This indicates if a fire has been detected 
(i.e., whether or not the fire input has been tripped). 
Panic
: This pertains to an "emergency" call-button in 
the elevator (lift) cab. 
- Reader 1 in Area X: This shows status topics 
for the selected elevator reader, and provides 
selections for controlling it (if you have the 
authority). Selections include lockout or 
reinstate card access, and/or change various 
operating characteristics. 
For details on the various reader modes, card modes, 
and class map settings, refer to the elevator 
configuration topic. 
- Elevator Floor Status: This area shows a list of 
the controlled floors that can be accessed 
through this elevator (lift) cab, plus the status of 
each floor, and provides selections to secure or 
desecure each floor (as accessed from this 
elevator / lift cab). 
RBA and Relay: This identifies the elevator controller 
relay associated with the specific floor (R
elay Board 
A
ddress 0 - 15, and Relay 1 - 8). 
- Relay Board Online: This lists the floor-relay 
board(s) for your selected elevator (lift) cab, and 
indicates any that are offline. 
Control & Status Panel Control & Status 
Elevators 