User Manual

Asset-Link 250 User Manual July 19, 2004
970-00047 Rev. 1.2
CSI Wireless©2004 Specifications subject to change without notice Page 3-2
Table 3-1 DB-25 Application I/O Connector Pin-Out
3.2 Power Input Specifications
3.2.1 Power Requirements
The Asset-Link unit operates from either a 12V or 24V DC electrical system over a
permissible range as shown in Table 3-2 and Table 3-3.
Parameter Rating Unit
Input Voltage -24 to 36 V DC
Table 3-2 Asset Power - Absolute Maximum Ratings
Parameter Min Typ Max Unit
Input voltage 7 - 36 V
Input current (TBD) - (TBD) A
Table 3-3 Asset Power Characteristics
3.2.2 Power Consumption Profile
Mode Typical Current Details
Power-Off
35uA (TBD) In this mode the unit will wake up every 2-63 seconds
for about 200 msec for activity check.
Active
Listening without GPS - TBD
Listening with GPS - TBD
Transmit (GSM or AMPs - TBD)
In this mode, the device continually checks for the
following:
i. Listen for FOCC messages (when Ears-
On)
ii. Check asset battery voltage
iii. Check I/O status and serial port.
iv. check exception, schedule and run meter
v. Update GPS fix (when GPS On)
Table 3-4 Power Consumption
3.2.3 Grounding Precautions
The negative connection (VIN_NEG from pins 24 & 12) should be chassis grounded
via two separate wires. One connected to a clean chassis point near the connection for
the positive power supply source (VIN_POS pins 25 & 13) and the other done at a
separate location from the other chassis ground connection to ensure a redundant
ground is available. This will prevent erroneous voltages on the digital outputs, and
allow the relay drivers to operate even if one connection is not a low impedance to