*** FRM-301 Fiber Optical Media Converter Rack Management ***
*** V3.42 ***
**************************************************************
Manager Configuration:
Access Password: disable
Community String #1 (Read/Write): public
Community String #2 (Read Only) : *
Access IP SNMP Community Trap
=============== ============== ====
#1:* public Yes
#2:* * *
#3:* * *
#4:* * *
Command Function Key:
'1': Edit Access IP#1 '3': Edit Access IP#3
'2': Edit Access IP#2 '4': Edit Access IP#4
'5': Edit Community#1 String (Read/Write)
'6': Edit Community#2 String (Read Only)
'7': User Password '8': Manager Password
'9': Access Password ON/OFF
'R': Delete All Setting
'ESC': Main Menu
The manager configuration has the ability to setup access for up to four (4)
different management workstations. The community strings act like passwords in
dealing with the device via SNMP protocol. By changing the community strings for
read / write ('public' in this case) and read only (undefined here) access, and
assigning a community string to an access IP, an administrator can control access to
the FRM301.
Enter the IP address of the management workstation that will be running the
GUIMGR software, the access authority and whether or not it will be sent trap
messages. Select "1":
IP('*':disable) ->172.24.1.126 #IP of manager
community '1' or '2'->1
#Manager has r/w privilege
trap 'y'es or 'n'o->y
#Manager will be sent trap messages