Chapter 3 Provisioning
21
3.2.4 Terminal Login
To enter "Console mode", a password is required. Normally, there is no password set from the factory. The
user password provides security to protect the system. From a Telnet connection, if you enter the wrong password
three times, the security system will not allow any login again for 15 minutes.
****************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** FRM220 NMC VER. 1.00 ***
****************************************
Login: admin
Password:
After entering the correct password, if required, you will see the main menu display on the screen as follows :
The FRM220 supports two dry contact alarms that are user configurable for a number of different alarm conditions.
Alarm conditions are configurable for alarms from Power, Fans, and UTP or Fiber link and Far End Fault states for local and
remote converters.
****************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** FRM220 NMC VER. 1.00 ***
****************************************
This Chassis ID:[00] Cascade:[Yes] Monitored Chassis ID:[00]
Chassis List:
#0:[X] #1:[ ] #2:[ ] #3:[ ] #4:[ ] #5:[ ] #6:[ ] #7:[ ] #8:[ ] #9:[ ]
<1>:SLOT #01 > NMC & Chassis <B>:SLOT #11 > FRM220-10/100I
<2>:SLOT #02 > FRM220-10/100I <C>:SLOT #12 > FRM220-10/100I
<3>:SLOT #03 > FRM220-10/100I <D>:SLOT #13 > FRM220-10/100I
<4>:SLOT #04 > FRM220-10/100I <E>:SLOT #14 > FRM220-10/100I
<5>:SLOT #05 > FRM220-10/100I <F>:SLOT #15 > FRM220-10/100I
<6>:SLOT #06 > FRM220-10/100I <G>:SLOT #16 > FRM220-10/100I
<7>:SLOT #07 > FRM220-10/100I <H>:SLOT #17 > FRM220-10/100I
<8>:SLOT #08 > FRM220-10/100I <I>:SLOT #18 > Empty
<9>:SLOT #09 > FRM220-10/100I <J>:SLOT #19 > Empty
<A>:SLOT #10 > FRM220-10/100I <K>:SLOT #20 > Empty
<->:Monitor previous chassis <+>:Monitor next chassis
<L>:SNMP System Configuration Setup
<M>:SNMP Manager Configuration Setup
<P>:Password Setup
<R>:Reboot <Z>:Logout
The card inventory of all slots in the rack is shown. In this example, the chassis is almost completely filled with
10/100 Ethernet in-band cards and of course the NMC card. If no card is found, the slot status will display 'Empty'.
The cards are number in slots #01~#20, left to right, looking from the front, and can be selected with single keyin of
1~9 or A~K. Pressing the card number will immediately display card's status and configuration screen. For details
of line card settings, please refer to Appendix A for the specific line card type. The other function keys are
explained below.
1: this key will immediately display the status of the power supplies and all fans (chassis).
L: the 'L' key enters the System Configuration screen, where the NMC card's networking settings are
configured.
M: the 'M' key will enter the Manager Configuration screen, where the manager workstation IP is configured,
the trap destinations may be setup and the SNMP community strings are defined.
P: this key will enter the user and password setting feature.
R: this key will reboot (hardware reset) the NMC.
Z: this key will logout of the console mode.
+: the plus key will select the next chassis in a cascaded stack.
-: the minus key will select the previous chassis in a cascaded stack.
Up to 10 chassis may be
cascaded and controlled from
a single point
20 slots are available in the
FRM220 chassis. One slot for
NMC and the rest for fiber
converter cards.