User manual

Chapter 3 Provisioning
26
For an example of configuration for Alarm #2, press '5' (five).
Alarm#2 Mode:
<0>: Disable -- ignore all alarm conditions
<1>: By Fans -- active if any fan fails
<2>: By User#2 -- active if any user#2 definition is met
<3>: Active -- for manual testing
<ESC>: Go to previous menu. Please select an item.
0 : This will completely disable Alarm #2. The relay dry contact will not close and the NMC ALM2 red LED will not light.
1 : This is the factory default setting. This alarm will only be off when one or both fans fail or are removed.
2 : This setting will take the user parameters and set the alarm according to failures in any parameters set under items 2,3,4.
3 : This selection will set the alarm for testing purposes. The ALM1 LED will light and dry contact for Alarm 1 will close.
User Alarm Definitions
Chassis [X]Power#1 [X]Power#2 [X]Fan#1 [X]Fan#2
Local [X]UTP_Link_Down [X]FX_Link_Down
[X]FEF_Detect [X]Remote_Power_Fail
Remote [X]UTP_Link_Down [X]FX_Link_Down
When alarm mode is set to "User", these definitions may be added to either User#1 or User#2. Any selected
item that fails will cause alarm activation. For chassis activated alarms, the user may select individual power or fan
combinations. For locally generated alarms, any copper, fiber, Far End Fault or Remote Power Failure can be
selected, in any combination to generate an alarm on failure from any installed Line Card. For any remotely
connected in-band converters, any copper, fiber, Far End Fault or Remote Power Failure may be used to trigger the
alarm relay.
Below is an example of user settings where Alarm#1 will be triggered by any chassis component failure
(power or fan). At the same time, Alarm#2 will be triggered if any local or remote copper or fiber link or remote
power has failure. The system is designed to allow very flexible use of the two dry contact alarms through
customized monitoring schemes.
****************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** FRM220 NMC VER. 1.01 ***
****************************************
This Chassis ID:[00] Cascade:[Yes] Monitored Chassis ID:[00]
SLOT #01 > NMC & Chassis [ Ver:1.00-1.01 ]
Power#1 Type:[AC90-250] Status:[OK ] Fan#1 RPM:[2910] Status:[OK ]
Power#2 Type:[DC36-72V] Status:[OK ] Fan#2 RPM:[2970] Status:[OK ]
Alarm#1 Status:[Inactive]
<1>: Mode: [By User#1]
<2>: User#1: Chassis [X]Power#1 [X]Power#2 [X]Fan#1 [X]Fan#2
<3>: Local [ ]UTP_Link_Down [ ]FX_Link_Down
[ ]FEF_Detect [ ]Remote_Power_Fail
<4>: Remote [ ]UTP_Link_Down [ ]FX_Link_Down
Alarm#2 Status:[Inactive]
<5>: Mode: [By User#2]
<6>: User#2: Chassis [ ]Power#1 [ ]Power#2 [ ]Fan#1 [ ]Fan#2
<7>: Local [X]UTP_Link_Down [X]FX_Link_Down
[X]FEF_Detected [X]Remote_Power_Fail
<8>: Remote [X]UTP_Link_Down [X]FX_Link_Down
<ESC>: Go to previous menu. Please select an item.