Chapter 3 Provisioning
28
3.2.8.4 Setup the FRM220
The following screens will show the detailed procedures to setup the networking for the FRM220 and prepare
for TFTP upgrade of the SNMP.
Once the console port is connected to a terminal, the following screen will display.
****************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** FRM220 NMC VER. 1.00 ***
****************************************
This Chassis ID:[00] Cascade:[Yes] Monitored Chassis ID:[00]
Chassis List:
#0:[X] #1:[ ] #2:[ ] #3:[ ] #4:[ ] #5:[ ] #6:[ ] #7:[ ] #8:[ ] #9:[ ]
<1>:SLOT #01 > NMC & Chassis <B>:SLOT #11 > FRM220-10/100I
<2>:SLOT #02 > FRM220-10/100I <C>:SLOT #12 > FRM220-10/100I
<3>:SLOT #03 > FRM220-10/100I <D>:SLOT #13 > FRM220-10/100I
<4>:SLOT #04 > FRM220-10/100I <E>:SLOT #14 > FRM220-10/100I
<5>:SLOT #05 > FRM220-10/100I <F>:SLOT #15 > FRM220-10/100I
<6>:SLOT #06 > FRM220-10/100I <G>:SLOT #16 > FRM220-10/100I
<7>:SLOT #07 > FRM220-10/100I <H>:SLOT #17 > FRM220-10/100I
<8>:SLOT #08 > FRM220-10/100I <I>:SLOT #18 > Empty
<9>:SLOT #09 > FRM220-10/100I <J>:SLOT #19 > Empty
<A>:SLOT #10 > FRM220-10/100I <K>:SLOT #20 > Empty
<->:Monitor previous chassis <+>:Monitor next chassis
<L>:SNMP System Configuration Setup
<M>:SNMP Manager Configuration Setup
<P>:Password Setup
<R>:Reboot <Z>:Logout
Press 'L' to enter the System Configuration Setup.
****************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** FRM220 NMC VER. 1.00 ***
****************************************
<< SNMP System Configuration Setup >>
Model= FRM220
S/N= 123456789
Target MAC Address= 00:02:ab:06:20:20
<1>: Target IP= 192.168.1.1
<2>: Target Netmask= 255.255.255.0
<3>: Target Gateway= 192.168.1.254
<4>: Target Name= FRM220
<5>: TFTP Server IP= 192.168.1.100
<6>: TFTP Download Kernel= linux.zip
<7>: TFTP Download File System= romfs.zip
<8>: Load default settings and write to system.
<9>: Do TFTP and Flash Kernel function.
<A>: Do TFTP and Flash File System function.
<ESC>: Write to system and go to previous menu.
Please select an item.
Using the menu items 1,2,3 & 5, keyin the networking values. If your notebook will run the TFTP daemon, set
its IP in the configuration for item 5, "TFTP Server IP".
If you have made any changes to items 1-5, you must write (ESC) and reboot (R) the NMC. Press 'ESC' to store
the results and at the main menu press 'R' and confirm with 'y'. The NMC will reboot completely in about 8
seconds.
These are the default TCP/IP settings.
You can directly connect by web
browser if you have configured your
Ethernet connected PC for this subnet.