Product Manual

EN•7
EN
SMARTPASS 120S
+OUT
+OUT
+IN
SETTINGS D250SE
SETTINGS SMARTPASS 120S
SYMBOLS AND TERMINALS
SYMBOLS
Fuse
See ”CABLE AND FUSE REQUIREMENTS”
Flashing lamp Continuously lit lamp
Solar panel Non critical consumer
Alternator Critical consumer
Smart alternator cable (red)
Smart alternator cable (red)
Ignition signal, +15 clamp
(DIN 72552)
Ignition signal, +15 clamp
(DIN 72552)
Chassis/Earth
Smart alternator cable
(red)
Type of
alternator
Not connected
Conventional
alternator
Connected Smart alternator
Chassis/Earth
Smart alternator cable
(red)
Type of
alternator
Battery select cable
(black)
Battery type
Not connected
Conventional
alternator
Not connected NORMAL
Connected Smart alternator Earth AGM
+12V LITHIUM-ION
Negative cable connection
(black)
Temperature sensor
Temperature sensor
Connection D250SE Connected to
Input Solar panel
+IN
Solar panel see “TECHNICAL
SPECIFICATION”
Input Alternator
+IN
Starter battery
Input Alternator SMARTPASS 120S via
connector plate or cable
Output Service battery
+OUT
Service battery
Output Service battery SMARTPASS 120S
Earth Connection
Chassis/Earth
• Solar panel (-)
• SMARTPASS 120S (-)
Smart alternator cable (red)
See “SETTINGS D250SE”
Battery select cable (black)
See “SETTINGS D250SE”
Connection SMARTPASS 120S Connected to
Input Alternator
+IN
Starter battery
Input Alternator D250SE via connector
plate or cable
Output Service battery
+OUT
Output Service battery D250SE
Output Consumers
+OUT
Non-critical consumers
Smart alternator cable (red)
See “SETTINGS SMARTPASS 120S”
Battery select cable (black)
0.2 m/0.6 ft.