User Manual

 EN • 9
EN
RESET
13.2V/5.0A
LiFe60
ERROR LAMP
FULLY CHARGEDREADY TO USE
POWER LAMP
RESET-BUTTON
BATTERIES WITH "UNDER VOLTAGE PROTECTION"
Some Lithium-ion batteries have an on-board UVP (under volt-
age protection) that disconnects the battery to avoid it becom-
ing too deeply discharged. This prohibits the CTEK charger
from detecting that there’s a battery connected. To bypass this,
the battery charger needs to open the UVP.
By pressing the RESET-button for 10 seconds, the charger
opens the UVP. During this process, the charging STEP 7 is
lit. Once the UVP has been opened and the battery is ready
to be charged, the charger automatically starts the charging
cycle.
OPERATING INSTRUCTIONS
1. Connect the charger to the battery.
2. Connect the charger to the wall socket. The
power lamp will indicate that the mains cable
is connected to the wall socket. The error lamp
will indicate if the battery clamps are incorrectly
connected. The reverse polarity protection will
ensure that the battery or charger will not be
damaged.
3. Follow the 8-step display through the charging
process.
The battery is ready to start the engine when
STEP 3 is lit.
The battery is fully charged when STEP 7 is lit.
4. Stop charging at any time by disconnecting the
mains cable from the wall socket.
20018058 B.indd 7 2016-04-07 12:33:52