Product Manual

4 • EN
BATTERY SIZE (Ah)
TIME TO 80% CHARGED
2Ah
2h
8Ah
8h
20Ah
20h
60Ah
60h
READY TO USE
The table shows the estimated time for empty battery to 80% charge
ERROR LAMP
If the error lamp is lit, check the following:
Is the chargers positive lead connected to the
batterys positive pole?
— Connect the charger according to page 6.
TECHNICAL SPECIFICATIONS
Charger model
XC 0.8
Model number
1054
Rated Voltage AC
220–240VAC, 50–60Hz
Charging voltage
7. 2V
Start voltage
3.7V
Charging current
0.8A max
Current, mains
0.2A rms (at full charging current)
Back current drain*
<1Ah/month
Ripple**
<4%
Ambient
temperature
-20°C to +50°C, output power is reduced
automatically at high temperatures
Charger type
4-step, fully automatic charging cycle
Battery types
All types of 6V lead-acid batteries
(WET, MF, Ca/Ca, AGM and GEL)
Battery capacity
1.2–100A h
Dimensions
142x51x36mm(LxWxH)
Insulation class
IP65
Weight
0.3kg
*) Back current drain is the current that drains the battery if the charger is not connected
to the mains. CTEK chargers has a very low back current.
**) The quality of the charging voltage and charging current is very important. A high
current ripple heats up the battery which has an aging effect on the positive electrode.
High voltage ripple could harm other equipment that is connected to the battery. CTEK
battery chargers produce very clean voltage and current with low ripple.
6V/0.8A
XC 0.8
FULLY CHARGED