Product Manual
EN•7
EN
SETTINGS D250SA
SYMBOLS
SYMBOLS
Connection Connected to
D250SA
Input Solar panel
+IN
• Solar panel (* see technical specification)
• Wind generator *
• Other DC source *
Input Alternator
+IN
• Starter battery
• Input Alternator SMARTPASS 120 via
connector plate or cable
Output Service battery
+OUT
• Service battery
• Output Service battery SMARTPASS 120
Earth Connection
• Chassis/Earth
• Solar panel (-)
• SMARTPASS 120 (-)
Smart alternator cable (red)
Ignition signal, +15 clamp (DIN 72552)
AGM Cable (black)
Chassis/Earth
SMARTPASS 120
Input Alternator
+IN
• Starter battery
• Input Alternator D250SA via
connector plate or cable
Output Service battery
+OUT
Output Service battery D250SA
Output Consumers
+OUT
Non-critical consumers
Fuse See ”CABLE AND FUSE RECOMMENDATIONS”
Flashing lamp
Continuously lit lamp
Solar panel Non critical consumer
Alternator Critical consumer
Smart alternator cable (red)
AGM Cable (black)
Ignition signal, +15 clamp
(DIN 72552)
Chassis/Earth
Smart alternator cable
(red)
Type of
alternator
AGM cable (black)
Charging
voltage
Not connected
Conventional
alternator
Not connected 14.4V
Connected Smart alternator Earth 14.7V