6. If the indicator for charge and maintenance charge are flashing alternately, this
may have the following causes:
Interruption of the charging process because a cable has become loose or because the
battery is not conducting.
The battery is sulphated. If the indicator flashes for more than 30 minutes the battery
may be defective and should be replaced.
If the flashing signal is flashing at intervals of more than 10 seconds, then there is a
high self discharge of the battery, indicating a bad battery.
BATTERY TYPES AND SETTINGS
MULTI US 3300 can easily be set for different types of batteries or conditions. The fol-
lowing recommendations should however only be seen as guidelines. Please consult the
battery manufacturer for further instructions.
Settings are made by pressing the ”MODE-button” and stepping forward one press at a
time until the required mode is reached, the button is then released. The selected mode is
saved in a memory in the charger and remains there even if the charger is switched off.
Mode 14.4V/0.8A
This mode is normally used for batteries <14 Ah.
Mode 14.4V/3.3A
Normal setting for wet batteries, maintenance free and for most Gel batteries. Some
gel batteries prefer a slightly lower voltage. Please consult the battery manufacturer
when in doubt.
Mode 14.7V/3.3A
This setting is recommended for a battery at temperatures < 5 degrees C. It is also
recommended for many AGM batteries like Optima, Maxxima and Odysses. Consult
your battery manufacturer when in doubt.