Operating instructions

14 • EN
CHARGING PROGRAMS AND OPTIONS COMBINATIONS
DESULPHATION SOFT START BULK ABSORPTION ANALYSE RECOND FLOAT PULSE
Current (A) Voltage (V)
15.8V 0.8A until 12.6V Increasing voltage to
14.4V. 0.8A
Declining current
14.4V
Checks if voltage
drops to 12V
13.6V
0.8A
12.7 V–14.4V
0.8–0.4A
+
15.8V 0.8A until 12.6V Increasing voltage to
14.7 V. 0.8A
Declining current
14.7 V
Checks if voltage
drops to 12V
13.6V
0.8A
12.7V14.7V
0.8–0.4A
+
RECOND
15.8V 0.8A until 12.6V Increasing voltage to
14.4V. 0.8A
Declining current
14.4V
Checks if voltage
drops to 12V
Max 15.8V
0.3A
13.6V
0.8A
12.7 V–14.4V
0.8–0.4A
+ +
RECOND
15.8V 0.8A until 12.6V Increasing voltage to
14.7 V. 0.8A
Declining current
14.7 V
Checks if voltage
drops to 12V
Max 15.8V
0.3A
13.6V
0.8A
12.7V14.7V
0.8–0.4A
15.8V 4.3A until 12.6V Increasing voltage to
14.4V. 4.3A
Declining current
14.4V
Checks if voltage
drops to 12V
13.6V
4.3A
12.7 V–14.4V
4.3A–2A
+
15.8V 4.3A until 12.6V Increasing voltage to
14.7V. 4.3A
Declining current
14.7 V
Checks if voltage
drops to 12V
13.6V
4.3A
12.7V14.7V
4.3A–2A
+
RECOND
15.8V 4.3A until 12.6V Increasing voltage to
14.4V. 4.3A
Declining current
14.4V
Checks if voltage
drops to 12V
Max 15.8V
1.5A
13.6V
4.3A
12.7 V–14.4V
4.3A–2A
+ +
RECOND
15.8V 4.3A until 12.6V Increasing voltage to
14.7V. 4.3A
Declining current
14.7 V
Checks if voltage
drops to 12V
Max 15.8V
1.5A
13.6V
4.3A
12.7V14.7V
4.3A–2A
Limit: Max 8h Max 20h Max 10h 3 minutes
30 min or 4h
depending on
battery voltage
10 days
Charge cycle
restarts if
voltage drops
Charge cycle
restarts if
voltage drops
20018888A MUS 4.3 Test&Charge, Manual, Print file.indd 14 2013-01-15 16:28:32