Operating instructions

10 • EN
READY TO USE
Thetableshowstheestimatedtimeforempty  battery to 80% 
charge
MODE
RECOND
12V/5A
MXS 5.0
BATTERY SIZE (AH) TIME TO 80% CHARGED
2Ah 2h
8Ah 8h
20Ah 5h
60Ah 15h
110A h 28h
STEP 1 DESULFATION
Detectssulfatedbatteries.Pulsingcurrentandvoltage,
removessulfatefromtheleadplatesofthe battery restoring
the battery capacity.
STEP 2 SOFT START
Testsifthe battery canacceptcha rge.Thissteppreventsthat
chargingproceedswith a defectbattery.
STEP 3 BULK
Chargingwithmaximumcurrentuntilapprox imately 80% bat-
tery capacity.
STEP 4 ABSORPTION
Chargingwithdecliningcurrenttomaximizeupto100%bat-
tery capacity.
STEP 5 ANALYSE
Testsifthe battery canholdcharge.Batter iesthatcannot
holdchargemayneedtobereplaced.
STEP 6 RECOND
Choos etheRecondprogramtoaddtheRecondsteptothe
chargingprocess.DuringtheRecondstepvoltageincreases
tocreatecontrolledgassinginthebattery.Gassingmixesthe
battery acidandgivesbackenergytothebattery.
STEP 7 FLOAT
Maintainingthe battery voltageatmaximumlevelbyprov id-
ing a cons tantvoltagecharge.
STEP 8 PULSE
Maintainingthe battery at95–100%capacity.Thecharger
monitorsthe battery voltageandgives a pulsewhenneces-
sarytokeepthe b attery fully charged.