Operating instructions

8 • EN
CHARGING PROGRAMS
SettingsaremadebypressingtheMODE-button. After abouttwosecondsthechargeractivatesthe selected program.The
selected programw illbe restarted nexttimethechargerisconnected.
THE TABLE EXPLAINS THE DIFFERENT CHARGING PROGRAMS:
PROGRAM BATTERY SIZE (AH) EXPLANATION TEMP RANGE
1.2–14Ah
Small battery program
14.4V/0.8A.Useforsmallerbatteries.
-4ºF122ºF
(-20°C–+50°C )
14–160Ah
Normal battery program
14.4V/4.3A.UseforWETbatteries,Ca/Ca,MF,GELbatteries
andmanyAGMbatteries.
41ºF122ºF
(+5°C–+50°C)
  
14–160Ah
Cold weather program
14.7V/4.3A . Useforchargingatlowtemperaturesandfor
powerAGM batterieslikeOptimaandOdyssey.
-4ºF41ºF
(-20°C–+5°C)
RECOND
14–160Ah
Recond program
15.8V/1.5A.Usetoretu rnenergytotheemptyWETandCa/Ca
batteries.Recondyour battery once peryearand after deep
dischargetomaximiselifetimeandcapacity.TheRecondpro-
gramaddsSTEP 6 tothenormal battery program.Frequentuse
oftheRecondprogrammaycausewaterlossinthebatteriesand
reduceservicelifeofelectronics.Contactyourvehicleandbat-
tery supplierforadvice.
-4ºF122ºF
(-20°C–+50°C )
20016551B MUS 4.3 NG, Manual, Print file 002.indd 8 2011-12-02 14:21:21