Operating instructions
EN
EN • 9
DESULPHATION SOFT START BULK ABSORPTION ANALYSE RECOND FLOAT PULSE
CURRENT (A) VOLTAGE (V)
15.8V 0.8A until 12.6V Increasing volt-
age to 14.4V.
0.8A
Declinin g cur-
rent. 14.4V
Checks if volt-
age drops to
12V
13.6V
0.8A
12.7 V–14. 4V
0.8–0.4A
15.8V 4.3A until 12.6V Increasing volt-
age to 14.4V.
4.3A
Declinin g cur-
rent. 14.4V
Checks if volt-
age drops to
12V
13.6V
4.3A
12.7 V–14. 4V
4.3–2A
15.8V 4.3A until 12.6V Increasing volt-
age to 14.7V.
4.3A
Declinin g cur-
rent. 14.7V
Checks if volt-
age drops to
12V
13.6V
4.3A
12.7V–14.7V
4.3–2A
RECOND
15.8V 4.3A until 12.6V Increasing volt-
age to 14.4V.
4.3A
Declinin g cur-
rent. 14.4V
Checks if volt-
age drops to
12V
Max 15.8V
1.5A
13.6V
4.3A
12.7 V–14. 4V
4.3–2A
Limit:
Max 8h Max 8h Max 20h Max 10h 3 minutes
30 min or 4h
depending
on battery
voltage
10 days.
Charge cycle
restarts if volt-
age drops
Charge cycle
restarts if volt-
age drops
20016551B MUS 4.3 NG, Manual, Print file 002.indd 9 2011-12-02 14:21:22